HY8:Inlet Control Computations: Difference between revisions

From XMS Wiki
Jump to navigationJump to search
No edit summary
No edit summary
 
(3 intermediate revisions by one other user not shown)
Line 1: Line 1:
Inlet control means that the amount of water the culvert barrel can carry is limited by the culvert entrance.  Flow passes through critical depth at the culvert entrance and is supercritical in the barrel.  There are several flow profiles possible, HY-8 simulates so-called Type A, B, C, and D conditions as shown below and as described in HDS-5.  These profiles are known as Type 1 (A, C) and Type 5 (B, D) within HY-8.  The various flow type properties may be found in HY-8 by selecting the '''Flow Types''' button from the Culvert Summary Table and are shown [[#HY-8 Flow Types|below]].  Because the flow in the barrel is supercritical, outlet losses and friction losses are not reflected in the headwater elevation.  The headwater elevation is a function of the entrance size, shape, and culvert type.  The computed inlet control headwater elevation is found by accessing the results of scaled physical model tests.  The logic for determining what inlet flow control type prevails is shown [[#Inlet Control Logic|below]] (from the original HY-8 help file).
Inlet control means that the amount of water the culvert barrel can carry is limited by the culvert entrance.  Flow passes through critical depth at the culvert entrance and is supercritical in the barrel.  There are several flow profiles possible, HY-8 simulates so-called Type A, B, C, and D conditions as shown below and as described in HDS-5.  These profiles are known as Type 1 (A, C) and Type 5 (B, D) within HY-8.  The various flow type properties may be found in HY-8 by selecting the '''Flow Types''' button from the Culvert Summary Table and are shown [[#HY-8 Flow Types|below]].  Because the flow in the barrel is supercritical, outlet losses and friction losses are not reflected in the headwater elevation.  The headwater elevation is a function of the entrance size, shape, slope, and culvert type.  The computed inlet control headwater elevation is found by accessing the results of scaled physical model tests.  The logic for determining what inlet flow control type prevails is shown [[#Inlet Control Logic|below]] (from the original HY-8 help file).


   
   
[[Image:InletControlFlowTypes.png|650px]]
[[Image:InletControlFlowTypes.png|450px]]
   
   


Line 8: Line 8:




==='''DETERMINE APPLICABLE INLET CONTROL EQUATION'''===
==='''Determine Applicable Inlet Control Equation'''===
#IF circle or box with IMPROVED INLETS then use INLET equations.
#IF circle or box with IMPROVED INLETS then use INLET equations.
#For Straight (previously called conventional) INLETS
#For Straight (previously called conventional) INLETS
Line 24: Line 24:
#:::      For Depression, HF = IH and check head on CREST.
#:::      For Depression, HF = IH and check head on CREST.


==='''INLET REGRESSION EQUATIONS (Q between Q at .5D and Q at 3D)'''===
==='''Inlet Regression Equations (Q between Q at 0.5D and Q at 3D)'''===
#CIRCULAR
#CIRCULAR
#:A.  See Straight inlet equations
#:A.  See Straight inlet equations
Line 64: Line 64:
   
   


==='''THROAT CONTROL TAPERED INLET'''===
==='''Throat Control Tapered Inlet'''===




Line 72: Line 72:
   
   


==='''FACE CONTROL-SIDE TAPERED INLET'''===
==='''Face Control-Side Tapered Inlet'''===




Line 89: Line 89:
   
   


==='''FACE CONTROL FOR SLOPE TAPERED INLET'''===
==='''Face Control For Slope Tapered Inlet'''===




Line 105: Line 105:
   
   


==='''CREST CONTROL'''===
==='''Crest ControlL'''===




Line 112: Line 112:
   
   


==='''OUTLET CONTROL PROCEDURES THAT PRODUCE AN INLET CONTROL PROFILE'''===
==='''Outlet Control Procedures That Produce an Inlet Control Profile'''===





Latest revision as of 22:24, 28 February 2018

Inlet control means that the amount of water the culvert barrel can carry is limited by the culvert entrance. Flow passes through critical depth at the culvert entrance and is supercritical in the barrel. There are several flow profiles possible, HY-8 simulates so-called Type A, B, C, and D conditions as shown below and as described in HDS-5. These profiles are known as Type 1 (A, C) and Type 5 (B, D) within HY-8. The various flow type properties may be found in HY-8 by selecting the Flow Types button from the Culvert Summary Table and are shown below. Because the flow in the barrel is supercritical, outlet losses and friction losses are not reflected in the headwater elevation. The headwater elevation is a function of the entrance size, shape, slope, and culvert type. The computed inlet control headwater elevation is found by accessing the results of scaled physical model tests. The logic for determining what inlet flow control type prevails is shown below (from the original HY-8 help file).


InletControlFlowTypes.png


Inlet Control Logic

Determine Applicable Inlet Control Equation

  1. IF circle or box with IMPROVED INLETS then use INLET equations.
  2. For Straight (previously called conventional) INLETS
    A. If Q is < Q at .5D, then assume LOW FLOW INLET CONTROL:
    i. calculate CRITICAL DEPTH (DCO)
    ii. calculate Section Properties
    iii. VH = (Q / AC)^2 / 64.4
    iv. IH = DCO * LMULT + (1 + KELOW) * VH * VHCOEF
    IF no Depression THEN IHI = IH + I1E
    For Depression, HF = IH and check head on CREST.
    B. If Q > Q at .5D, but < Q at 3D, then use INLET REGRESSION EQUATIONS.
    C. If Q > Q at 3D, then assume HIGH FLOW INLET CONTROL.
    i. IH = (Q / CDAHI)^2 + .5 * RISE
    ii. IF no Depression THEN IHI = IH + I1E
    For Depression, HF = IH and check head on CREST.

Inlet Regression Equations (Q between Q at 0.5D and Q at 3D)

  1. CIRCULAR
    A. See Straight inlet equations
    B. SIDE TAPERED ELLIPTICAL TRANSITION, THROAT CONTROL
    ZZ = Q / SQR(RISE ^ 5), Y = LOG(ZZ) / 2.30258
    i. IF n < .015 THEN SMOOTH PIPE IMPROVRD INLET.
    ii. If n >=.015 then ROUGH PIPE IMPROVED INLET.
    iii. Calculate THROAT CONTROL
    iv. Calculate FACE CONTROL
    v. IF Depression Then CW = CWF, calculate CREST control.
    C. SIDE TAPERED RECTANGULAR TRANSITION or SLOPE TAPERED
    i. Calculate THROAT CONTROL
    ii. Calculate FACE CONTROL
    iii. IF Depression Then CW = CWF, calculate CREST control.
  2. BOX CULVERTS
    A. See Straight inlet equations
    B. SIDE TAPERED RECTANGULAR TRANSITION or SLOPE TAPERED
    i. Calculate THROAT CONTROL
    ii. Calculate FACE CONTROL
    iii. IF Depression Then CW = CWF, calculate CREST control.
  3. PIPE ARCHES AND ELLIPSES
    A. See Straight inlet equations
  4. IRREGULAR SHAPE
    A. See Straight inlet equations


Straight Inlet Equations

  1. For IRREGULAR shape, X = Q / (AC * SQR(RISE))
    IF X <= .5 THEN IH = (A(1) * (X / .5)) * RISE
    ELSE IH = (A(J - 1) + (A(J) - A(J - 1)) * ((X - J + 2) / INC)) * RISE
  2. For all others shapes, X = Q / (SPAN * SQR(RISE^3)): SR = SR(IC)
    IH = (A + (B + (C + (D + (E + F * X) * X) * X) * X) * X - SR * S0) * RISE
  3. Headwater elevation (IHI) = IH + I1E if no Depression.
  4. For Depression, CREST headwater is checked.


Throat Control Tapered Inlet

  1. X = Q / (SPAN * SQR(RISE^3))
  2. HT=RISE*(.1295033+(.3789944+(-.0437778+(4.26329E-03-1.06358E-04*X)*X)*X)*X)


Face Control-Side Tapered Inlet

  1. ZZ = Q / (BF * SQR(RISE^3))
  2. Calculate UNSUBMERGED: HF1 = (.56 * RISE) * (ZZ ^ .66667)
  3. Calculate SUBMERGED
    A. For bevels: HF3 = (.0378 * (ZZ * ZZ) + .86) * RISE
    IF HF1 > RISE THEN HF = HF3
    IF HF1 < RISE THEN HF = HF1
    IF HF1 >= HF3 THEN HF = HF1
    B. For other edges: HF2 = (.0446 * (ZZ * ZZ) + .84) * RISE
    IF HF1 > RISE THEN HF = HF2
    IF HF1 < RISE THEN HF = HF1
    IF HF1 >= HF2 THEN HF = HF1


Face Control For Slope Tapered Inlet

  1. ZZ = Q / (BF * SQR(RISE^3))
  2. Calculate UNSUBMERGED: HF1 = (.5 * RISE) * (ZZ ^ .66667)
    A. For bevels: HF3 = (.0378 * (ZZ * ZZ) + .7) * RISE
    IF HF1 > RISE THEN HF = HF3
    IF HF1 < RISE THEN HF = HF1
    IF HF1 > HF3 THEN HF = HF1
    B. For other edges: HF2 = (.0446 * (ZZ * ZZ) + .64) * RISE
    IF HF1 > RISE THEN HF = HF2
    IF HF1 < RISE THEN HF = HF1
    IF HF1 > HF2 THEN HF = HF1


Crest ControlL

  1. HC = .5 * (Q / CW) ^ .66667


Outlet Control Procedures That Produce an Inlet Control Profile

STEP

  1. Compute critical depth (dco)
  2. Compute normal depth (dno)
  3. Compute fullflow if nomograph solution assumed "6-FFt or FFc".
  4. If dno > .95(rise), assume fullflow "6-FFn".
  5. If dno > dco, assume mild slope (SEE OUTLET.DAT).
  6. If dno <= dco, assume steep slope.
    A. If twh is >= So(L) + rise, assume fullflow "4-FFt".\
    B. If twh is >= rise, outlet submerged, assume inlet unsubmerged.
    C. If twh is < rise, outlet is unsubmerged, assume inlet unsubmerged.
    i. Assume headwater (oh) = inlet control headwater (ih)
    Calculate S2 curve "1-S2n" for outlet depth.
    If oh >= rise, inlet submerged "5-S2n"
    ii. If twh > headwater, tailwater drowns out jump.
    Calculate M1 curve "3-M1t".
    If culvert flows part full, "7-Mit".
HY8Inlet Control Chart.jpg