Revision as of 20:22, 16 December 2011
The input variables required for this calculation is the following:
- h/ri -- Ratio of roughness element height divided by hydraulic radius taken about the top of the roughness element.
- Height of the roughened section (h)
The following figure shows the flow regimes and variables for an increased resistance energy dissipator implemented in a circular culvert.
Variables from the figure
- L -- Length from beginning of one roughness element to the beginning of the next roughness element.
- h -- height of roughness element
- Di -- diameter of roughened section (opening)