Template:MODLFOW Model Calibration Using Wells Pumping Rate Workflow: Difference between revisions

From XMS Wiki
Jump to navigationJump to search
(Created page with "{|class="mw-collapsible mw-collapsed" style="width:80%; border:1px solid #CDB7B5; margin-bottom:0.4em;" |- !style="text-align:left;"|1. Define MODFLOW parameters. |- | :Define...")
 
m (Protected "Template:MODLFOW Model Calibration Using Wells Pumping Rate Workflow" ([Edit=Allow only administrators] (indefinite) [Move=Allow only administrators] (indefinite)))
 
(One intermediate revision by the same user not shown)
Line 19: Line 19:
|-
|-
|
|
:#Go to “MODFLOW | Optional Packages | Well”
:#Select '''MODFLOW'' | ''Optional Packages'' | '''WEL - Well''' to open the [[GMS:WEL Package|''MODFLOW Well Package'']] dialog.
:#Enter a “Q factor” of -1.0
:#For the ''Q factor'' column, enter "-1.0".
|}
|}
{|class="mw-collapsible mw-collapsed" style="width:80%; border:1px solid #CDB7B5; margin-bottom:0.4em;"
{|class="mw-collapsible mw-collapsed" style="width:80%; border:1px solid #CDB7B5; margin-bottom:0.4em;"
Line 27: Line 27:
|-
|-
|
|
:# Go to “MODFLOW | Global Options”
:# Select ''MODFLOW'' | '''Global Options''' to open the [[GMS:Global Options/Basic Package|''MODFLOW Global/Basic Package'']] dialog.
:#  Change the “Run options” to “Parameter Estimation”
:#  Change the ''Run options'' to ''Parameter Estimation''.
:#  Create head observation in map module.
|}
|}
{|class="mw-collapsible mw-collapsed" style="width:80%; border:1px solid #CDB7B5; margin-bottom:0.4em;"
{|class="mw-collapsible mw-collapsed" style="width:80%; border:1px solid #CDB7B5; margin-bottom:0.4em;"
|-
|-
!style="text-align:left;"|4. Run MODFLOW.
!style="text-align:left;"|4. Create head observations in the Map module.
|-
|
: See the [[MODFLOW Model Calibration Workflow|MODFLOW Model Calibration Workflow]].
|}
{|class="mw-collapsible mw-collapsed" style="width:80%; border:1px solid #CDB7B5; margin-bottom:0.4em;"
|-
!style="text-align:left;"|5. Run MODFLOW.
|-
|-
|
|
{{GMS MODFLOW Save and Run Workflow}}
{{GMS MODFLOW Save and Run Workflow}}
|}<noinclude>[[Category:MODFLOW Workflow Templates|Calibration]] </noinclude>
|}<noinclude>[[Category:MODFLOW Workflow Templates|Calibration]] </noinclude>

Latest revision as of 19:46, 3 August 2021

1. Define MODFLOW parameters.
Define the MODFLOW parameters using the well and the pumping rate assigned to the well.
  1. Select MODFLOW | Parameters to open the Parameters dialog.
  2. Click the New button.
  3. Turn on Show all columns checkbox.
  4. Change the Type column to "WELL".
  5. In the Key column, enter actual pumping rate.
  6. Enter inverse of pumping rate value in the Value column.
  7. Enter Min and Max values greater than 0. These and “Value” will be multiplied by the Q factor later which will be negative 1, so positive values here will actually be negative.
  8. Turn on Log Xform
2. Define well options.
  1. Select MODFLOW | Optional Packages | WEL - Well' to open the MODFLOW Well Package dialog.
  2. For the Q factor column, enter "-1.0".
3. Set calibration parameters.
  1. Select MODFLOW | Global Options to open the MODFLOW Global/Basic Package dialog.
  2. Change the Run options to Parameter Estimation.
4. Create head observations in the Map module.
See the MODFLOW Model Calibration Workflow.
5. Run MODFLOW.
  1. Save Save Macro.svg the project.
  2. Run MODFLOW Run MODFLOW Macro.svg.