The following controls specify how the ADH model will solve (operate and iterate through) the simulation.
Non-Linear Iterations
Maximum number of iterations per time step positive integer edit field provides the value for the IP NIT or IP FNI card.
Iteration tolerance positive real number edit field provides the value for the IP NTL card.
Reduce timestep / Accept solution radio group specifies with the inclusion of the IP NIT or IP FNI card respectively.
Increment tolerance check box and the associated Residual tolerance positive real number edit field correlates with the IP ITL card. The card is included in the simulation if this option is checked.
Linear Iterations By Solver
Maximum number of iterations positive integer edit field provides the value for the IP MIT or IP FLI card.
Stop the solution / Proceed to the next non-linear iteration radio group specifies with the inclusion of the IP MIT or IP FLI card respectively.
Operation
Incremental memory allocation block size check box with positive integer edit field correlates with the OP INC card.
Iterative solver pre-conditioner check box and the associated pre-conditioner combo-box and Block specification check box with positive integer edit field control group is tied to the OP PRE and OP BLK cards.
Include vessel movement library check box includes the OP BT card in the simulation when checked.