GMS:GMG Package: Difference between revisions

From XMS Wiki
Jump to navigationJump to search
No edit summary
No edit summary
Line 12: Line 12:
** "(1) Cooley adaptive"  
** "(1) Cooley adaptive"  
** "(2) RRR adaptive"   
** "(2) RRR adaptive"   
* Maximum damping (DUP)
* ''Maximum damping (DUP)''
* Minimum damping (DLOW)
* ''Minimum damping (DLOW)''
* Maximum head change (CHGLIMIT)
* ''Maximum head change (CHGLIMIT)''
* ''Output flag (IOUTGMG)'' – Flag that controls the output of the GMG solver. Values can be 0–4.
* ''Output flag (IOUTGMG)'' – Flag that controls the output of the GMG solver. Values can be 0–4.
** 0 = Only the solver inputs are printed.
** 0 = Only the solver inputs are printed.
Line 21: Line 21:
** 3 = Same as 1 except the output is sent to the terminal instead of the output file.
** 3 = Same as 1 except the output is sent to the terminal instead of the output file.
** 4 = Same as 2 except the output is sent to the terminal instead of the output file.
** 4 = Same as 2 except the output is sent to the terminal instead of the output file.
* Maximum head output (IUNITMHC)
* ''Maximum head output (IUNITMHC)''
* ''Multi-grid preconditioner smoothing (ISM)'' – Flag that controls the type of smoother used in the multi-grid preconditioner.
* ''Multi-grid preconditioner smoothing (ISM)'' – Flag that controls the type of smoother used in the multi-grid preconditioner.
** "(0) ILU smoothing" – This smoothing requires an additional vector on each multigrid level to store the pivots in the ILU factorization.
** "(0) ILU smoothing" – This smoothing requires an additional vector on each multigrid level to store the pivots in the ILU factorization.

Revision as of 15:10, 6 July 2016

MODFLOW
Pre-processing
MODFLOW Commands
Building a MODFLOW Model
Map to MODFLOW
Calibration
Packages Supported in GMS
Saving a MODFLOW Simulation
Importing MODFLOW Files
Unsupported MODFLOW Features
Run MODFLOW
Post-processing
MODFLOW Display Options
MODFLOW Post-Processing Viewing Options
Reading a MODFLOW Simulation
Tutorials
Packages
Flow: BCF6, HUF, LPF, UPW
Solvers:

DE4, GMG, NWT, PCG,

PCGN, LMG, SIP, SOR,

SMS
Other:

BAS6, BFH, CHD1, CLN,

DRN1, DRT1, EVT1, ETS1,

GAGE, GHB1, GNC, HFB1,

HUF, LAK3, MNW1, MNW2,

OUT1, RCH1, RIV1, SFR2,

STR1, SUB1, SWI2, WEL1,

UZF1

The GMG package is one of the solver packages for MODFLOW supported by GMS. The GMG solver is an iterative solver based on a multi-grid approach.

Parameters include:

  • Inner convergence residual (RCLOSE) – The algorithm computes the 12-norm of the residual and compares it against RCLOSE.
  • Maximum inner iterations (IITER) – For each linear solution. The default is 100. Specify a smaller number for nonlinear problems to prevent an excessive number of inner iterations.
  • Outer convergence residual (HCLOSE) – For nonlinear problems. After each linear solve (inner iteration), the maximum norm of the head change is compared against HCLOSE. Can be set to a large number for linear problems. Ignored if Maximum outer iterations is 1.
  • Maximum outer iterations (MAXITER) – Also referred to as MXITER. For linear problems, set to 1. For nonlinear problems, set to a higher number though it is usually unnecessary to go above 100.
  • Damping parameter (DAMP) – A value of 1.0 should be used for linear problems. For nonlinear problems, a value less than 1.0 but greater than 0.0 may be necessary to achieve convergence.
  • Damping option (IADAMP) – Flag that controls adaptive damping. Contains the following options:
    • "(0) Constant"
    • "(1) Cooley adaptive"
    • "(2) RRR adaptive"
  • Maximum damping (DUP)
  • Minimum damping (DLOW)
  • Maximum head change (CHGLIMIT)
  • Output flag (IOUTGMG) – Flag that controls the output of the GMG solver. Values can be 0–4.
    • 0 = Only the solver inputs are printed.
    • 1 = For each linear solve, prints the number of PCG iterations, the value of the damping parameter, the 12-norm of the residual, and the maximum norm of the head change and its location (column, row, layer). At the end of a time/stress period, the total number of GMG calls, PCG iterations, and a running total of PCG iterations for all time/stress periods are printed.
    • 2 = The convergence history of the PCG iteration is printed, showing the 12-norm of the residual and the convergence factor for each iteration.
    • 3 = Same as 1 except the output is sent to the terminal instead of the output file.
    • 4 = Same as 2 except the output is sent to the terminal instead of the output file.
  • Maximum head output (IUNITMHC)
  • Multi-grid preconditioner smoothing (ISM) – Flag that controls the type of smoother used in the multi-grid preconditioner.
    • "(0) ILU smoothing" – This smoothing requires an additional vector on each multigrid level to store the pivots in the ILU factorization.
    • "(1) SGS smoothing" – Symmetric GaussSeidel (SGS) smoothing.
  • Multi-grid preconditioner coarsening (ISC) – Flag that controls semi-coarsening in the multi-grid preconditioner.
    • "(0) Row, Col., Layer" – Coarsens all the rows, columns and layers.
    • "(1) Row, Col." – Coarsens all the rows and columns.
    • "(2) Col., Layer" – Coarsens all columns and layers.
    • "(3) Row, Layer" – Coarsens all rows and layers.
    • "(4) None" – No coarsening.
  • Relocation parameter (RELAX) – Used to improve the spectral condition number of the ILU preconditioned system.

For more info on the GMG solver look at the following document:

Wilson, John D., and Richard L. Naff. MODFLOW-2000, The US Geological Survey Modular Ground-Water Model—GMG Linear Equation Solver Package Documentation. No. 2004-1261. 2004. [1]
The MODFLOW GMG Solver package dialog.