HY8:Increased Resistance in Box Culverts: Difference between revisions
From XMS Wiki
Jump to navigationJump to search
No edit summary |
|
(No difference)
|
Revision as of 20:08, 9 January 2013
The input variables required for this calculation are the following:
- h/ri -- Ratio of roughness element height divided by hydraulic radius taken about the top of the roughness element.
- Height of the roughened section (h)
The following figure shows the flow regimes and variables for an increased resistance energy dissipator implemented in a circular culvert.
Variables from the figure
- L -- Length from beginning of one roughness element to the beginning of the next roughness element.
- h -- height of roughness element
- Di -- diameter of roughened section (opening)