The input variables required for this calculation is the following:

  • H/RI -- Ratio of roughness element height divided by hydraulic radius taken about the top of the roughness element.
  • Height of the roughened section (h)


The following figure shows the flow regimes and variables for an increased resistance energy dissipator implemented in a circular culvert.

HY8fig7-6.jpg

Variables from the figure

  • L -- Length from beginning of one roughness element to the beginning of the next roughness element.
  • h -- height of roughness element
  • Di -- diameter of roughened section (opening)