SMS:SRH-2D Errors: Difference between revisions

From XMS Wiki
Jump to navigationJump to search
No edit summary
Line 184: Line 184:
| Shape of pressure zone is not acceptable for a parabolic type bridge ceiling
| Shape of pressure zone is not acceptable for a parabolic type bridge ceiling
| Ensure that the pressure zone, between the pressure flow arcs, is rectangular in shape
| Ensure that the pressure zone, between the pressure flow arcs, is rectangular in shape
|-
| SRH-2D
| 9669
| Program stopped due to the following:
Wrong IFACE matching occurred in structure_internal.f90 #4
Error Code is:    9669
| Ensure that the area between the pressure zone arcs with overtopping turned on is rectangular in shape and that the elements in between the arcs are quads (rectangles).
| Create a new mesh with a rectangle between pressure flow arcs and which has quads in this area using the patch mesh generation method.
|}
|}



Revision as of 22:35, 27 February 2018

This is a list of known error messages produced by SRH-2D. These errors will appear during the model run.

List of Error Messages

The first three columns in the table are sortable. Simply click the small arrows on the right side of the column header to sort in ascending or descending order.

The columns in the table include:

  • Location indicates whether the error occurs in the SRH-2D Preprocessor or in SRH-2D itself.
  • Error Code gives the Error Code (if any).
  • Error Text from Model gives the full text of the error message. Errors that do not produce any error text will have "no text" in this field.
  • Description gives more details about the error.
  • Solution gives steps necessary to correct the issue.
Location Error Code Error Text from Model Description Solution
SRH-2D 1 Stopped in uti_qwin_xyplot.f90 TIME_SIMU Inconsistent time control The end time is prior to the start time in the model control. Adjust so it is later than the start time.
PreSRH-2D 1 unable to open srhhydro file! Unable to open srhhydro file The path length for the SMS project is too long. Therefore, the SRH-2D preprocessor could not read the exported files from SMS. Reduce the path length to less than 300 characters.
PreSRH-2D 1 Element ID is not consecutive The mesh element ID's have been mismatched since some mesh nodes were modified and not renumbered (which causes SMS to automatically update the mesh element ID's) The mesh nodes need to be renumbered using the Renumber command under the Nodes menu in the Mesh module
SRH-2D No cells cover an obstruction in structure_obstruction.f90 Obstruction feature area of influence does not cover the centroid of at least one element The "Obstruction Width/Diameter:" value in the Obstructions Properties dialog is set to "0" and/or an obstruction arc is positioned just beyond half the width/diameter defined in the properties from the centroid of a mesh element.
SRH-2D 5 Stopped in structure_culvert.f90 ICELL error#5 BC arc mesh snapping does not match inactive material zone snapping Some paired arc 1D structures require an "unassigned" material zone between the structure arcs. If the material zone snapping does not match the BC arc snapping, there will be element inactivity problems at the face of the structure.
SRH-2D More than 99 obstructions exist SRH-2D has a built in limit to how many obstructions can be included in a model. Currently this limit is 99. Reduce the number of obstructions to 99 or fewer.
Pre SRH-2D Errors from final_touch.f90 **** on MONITOR LINE#n
a face cannot be found given two mesh points

Two points are: xx xx
Check your mesh node list; you may do this using _SIF.dat file directly!

Monitor line spans a mesh void (hole) Reconfigure the monitor line. Monitor lines cannot span holes in the mesh.
SRH-2D If you specify a z elevation to a bridge arc that is too high in the structures exercise, SRH doesn't run. bug
SRH-2D 2 ALL INLET cells are dry from bc_mdot2.f90! Code may have blow up due to input errors or too-large time step. Material polygons near inflow are unassigned This occurs when the material coverage has not been linked to the simulation. Also occurs when all material polygons covering the inflow BC are have an "unassigned" material type. This can also occur if no boundary conditions providing an inflow source have been included in the simulation.
SRH-2D FATAL ERROR The code diverged; further reduction of time step would help the convergence! Too large of a time step Reduce the size of the computational time step in the model control
SRH-2D 3 bad mesh ! Stopped in indx_conn.f Problem in mesh, often due to overlapping elements. Check if problem cell (element) id is listed. Otherwise, examine mesh quality in SMS.
SMS No mesh that matches the scalar set. No mesh that matches the scalar set. The solution file does not correspond to the mesh in the project, or node numbering of the mesh has been changed, invalidating the solution. Take care when making edits to the mesh and renumbering the nodes. Any previous results will be invalidated when nodes are renumbered.
WSE error directly under the bridge in the form of waves oscillating through the channel Use larger, quadrilateral elements in the deepest areas of flow. This could also mean that the piers need to be switched to obstructions. Lowering the time step may also help.
SMS The following coverage(s) have an unsupported type and will be converted to area property: (Name of Coverage(s) Listed) Opening a map file with out an accompanying project file. If the coverage type is under Model (which the .map file provided indicated it was) then the type is stored in the project file so that error will appear when opening just the *.map file.
SRH-2D Exit code 0 Exit code 0 SRH-2D has stopped or finished (whether "successfully executed" or not), further troubleshooting is required if it has not finished running successfully.
1 Error code 1 srhmat file does not exist File didn't export successfully, Make sure assigned materials in the materials coverage, possibly too many monitoring lines (20 or less okay)
PreSRH-2D forrtl: severe (157): Program Exception - access violation Set up file location Preferences to the correct location for SRH-Pre
PreSRH-2D MESH-UNIT: Enter one of the following options for the unit of the mesh Mesh unit error SRH requires that vertical and horizontal units be in either meters or U.S survey feet
SRH-2D 8 Inconsistent cell ID in mesh_connectivity: maybe due to wrong nodestring Possibly due to overlapping elements
PreSRH-2D 1 Stopped in add_nbdf.90 DIS Issue with BC nodestrings In this case, this issue was from a bug where SMS was exporting the nodestring in the SRHGEOM file incorrectly for two HY8 culvert arcs. SMS was essentially writing the same string of nodes for both the upstream and downstream culvert arcs.
SRH-2D 1 Stopped in face_wd.f90 PRESS#1 Issue with Pressure Flow BC and "Piers" In this problem, SRH2D did not allow holes in the mesh that represented bridge piers within the Pressure flow zone. This is only a problem in SMS v.12.1 and the SRH executable supplied with it. SMS 12.2 and the SRH executable supplied with it now allows holes in the mesh within Pressure zones. The same error will also be shown if an "unassigned" material type is specified in the pressure zone, again this is only a problem in SMS v12.1 and the SRH exe supplied with it, 12.2 allows "unassigned" material types in the pressure flow zone.
SRH-2D Program Stopped as Mesh is different in RST file

One of the following is different:
Ncell Nvert Nface Nclfc Nclvt in RESTART file
do not match those in the input file
Ncell Nvert Nface Nclfc Nclvt
in restart file are: 13604 7374 20977 41693 41693
in casename.GRD file are: 15459 8277 23735 47225
Mesh topology has to be the same for irest>=1 or init_method=3

Using a restart file that was created with another mesh Restart files can only be used with simulations using the exact same mesh.
PreSRH-2D Could not find a mesh cell which contains the monitoring point! Check if you have the right input of (X Y) coordinates for a monitoring points Monitor Point Outside of Mesh Monitor point must be somewhere within a mesh element.
SRH-2D 6940 Ensure that areas upstream of the upstream culvert location and areas downstream of the downstream culvert location have a valid material type assigned.
SRH-2D 1 Stopped in structure_pressure_flow.f90 PARA DISTANCE Shape of pressure zone is not acceptable for a parabolic type bridge ceiling Ensure that the pressure zone, between the pressure flow arcs, is rectangular in shape
SRH-2D 9669 Program stopped due to the following:

Wrong IFACE matching occurred in structure_internal.f90 #4 Error Code is: 9669

Ensure that the area between the pressure zone arcs with overtopping turned on is rectangular in shape and that the elements in between the arcs are quads (rectangles). Create a new mesh with a rectangle between pressure flow arcs and which has quads in this area using the patch mesh generation method.

Related Topics