The ADCIRC Model Control dialog is where important project parameters are chosen and defined. The six different tabs are listed below.

  • General Parameters – Contains such options as model type, cold/hot start, terms, maximum number of iterations, bottom stress/friction, etc.
  • Model Formulation
  • Timing – Defines simulation run time, start time, and time step options
  • Output
  • Wind – Enables specific wind types and their options
  • Nodal Attributes
  • Harmonics Analysis – Defines tidal constituents and harmonic analysis options
  • Wind – Enables specific wind types and their options

General Tab

File:File:ADCIRC MC-General.png
ADCIRC Model Control dialog showing the General Parameters tab

The General parameters tab contains the following:

  • Simulation Titles – Includes the Project Title and Run ID.
  • Model Type – 2D DI, 3D VS, 3D DSS. The two dimensional depth integrated is the only option that is recommended for commercial applications at this time.
  • Initial Values – Cold Start, Hot Start 1, Hot Start2. This option allows choosing a file to initialize the values of water level and velocity for a simulation. The files must have been saved from a previous run using the same finite element grid.
  • Coriolis Option – Constant, Variable. The type of Coriolis forcing used does not impact run time for ADCIRC at all. Variable should be used when the coordinate system is geographic. In this case, ADCIRC will load a Coriolis coefficient for each node based on the latitude of the node. If wanting to run ADCIRC in rectilinear coordinates, specify a constant Coriolis option because the model does not support reprojection from rectilinear to geographic to determine individual latitudes for each node.
  • Minimum Angle For Tangential Flow
  • Terms – Finite Amplitude Terms, Advective Terms, Time Derivative Terms
    • Wetting/Drying – Activating this option will cause an Options button to appear. Clicking this button will bring up the Wetting/Drying Parameters dialog.
  • Solver Type – Lumped, Direct Banded, Iterative JCG – The Iterative JCG is the default and recommended solver. The other options are in the interface for backward compatibility and analytic tests.
  • Absolute Convergence Criteria
  • Maximum Number of Iterations per Time Step
  • Generalized Properties – Wave Continuity, Lateral Viscosity
  • Bottom Stress/Friction – Constant Linear, Constant Quadratic, Constant Hybrid, Varying Linear, Varying Quadratic, Friction Coefficient – The "Constant Linear" option should only be used for analytical cases when verifying the code. Linear friction causes overdamping in deep water. For "Constant Quadratic" the value of TAU0 should be set based on the principle depth. A value of TAU0 = 0.005 is suggested for deeper water (greater than 10 m depth). For shallow water, TAU0 = 0.02 is recommended. If the domain includes both shallow and deep water, consider the varying quadratic option.
Wetting/Drying Parameters dialog accessed through the General tab of the ADCIRC Model Control dialog

Model Formulation Tab

Timing Tab

ADCIRC Model Control dialog showing the '"Timing tab

Important parameters to be aware of:

  • Ramp Function Value – This value is a period of time, starting at the beginning of a simulation, that allows the full forcing of the tidal constituents to be gradually applied to the model. This prevents any issues or negative effects from occurring that could harm the results of a simulation.[1]
  • Reference time – Specifies that the extracted tidal constituents are earlier or later than the start time of the simulation (see ADCIRC documentation Reftime).
  • Start Day – The start time of a project
  • Time Step – Time interval between successive measurements
  • Run Time – Total length of time a simulation is run
  • End Time – Day when simulation should finish

Tidal/Harmonics Tab

ADCIRC Model Control dialog showing the Tidal/Harmonics tab

Tidal constituents are variations in tides that are created by different frequencies of astronomical forcing. They arise due to the gravitational influences of the Moon and Sun on the Earth, the tilt of the rotational axis of the Earth, the elliptical shape of the Moon's orbit around the Earth, the shape of the Earth's orbit around the Sun, and other such factors. Many constituents have been defined and are classified based on their cycle lengths. Most of the tidal constituents used in the ADCIRC interface of SMS are either diurnal (one cycle per day) or semidiurnal (two cycles per day) in nature. Harmonic constituents are those variations that have periods of less than half a day. For a table of commonly used constituents see Principal Tidal Constituents.[1]

SMS uses the following databases to provide the tidal constituent data to an ADCIRC simulation:

  • LeProvost – The LeProvost database is a set of *.legi files which provide amplitude and phase information. The LeProvost database can be downloaded at: sms.aquaveo.com/leprovost.zip.
An image of the LeProvost tidal database domain coverage can be found here – LeProvost Domain.png[2]
  • ADCIRC – The ADCIRC database includes a grid file and a harmonics file that uses an *.exe extractor to put information into SMS. The ADCIRC database can be downloaded at: sms.aquaveo.com/adcirctides.zip. More information about the ADCIRC database can be obtained at the ADCIRC web page: ADCIRC Tides Databases. The ADCIRC database is only valid for projections in North America.

The path to each database on a computer must be specified in the Preferences dialog by going to Edit | Preferences then selecting the File Locations tab. The two tidal constituent databases (LeProvost and ADCIRC) are only accessible if the SMS project has a global (not local) display projection.

In the New Constituent dialog, the radio buttons that allow selecting either of these databases are either enabled or grayed out depending on the display projection setting.

Example of the New Constituent dialog.

Wind Tab

ADCIRC Model Control dialog showing the Wind tab

ADCIRC can model and compute wind velocities and stresses. The ADCIRC model is able to use wind data from a variety of different file types. The SMS interface is not able to read and create all of the available wind data file types. There are three types that SMS is able to read and create. Even though SMS does not read and create these other file types, it does tell ADCIRC that there is data there, where it is, and how to access it for a simulation to run correctly.

One of the parameters found in the fort.22 file (Single File Meteorological Forcing Input File) will tell which of the wind data file types SMS can read and create. The first parameter specified in the fort.22 file is called the Node Wind Stress (NWS) value. This value represents what type of wind data is in the file. It can range from 0 to 100+. SMS can read and create fort.22 files that are of the NWS value of 1, 2, or 5. All other values of the NWS value are only shown and directed to the ADCIRC model by SMS so that a simulation will run correctly.

Fleet Wind File Options dialog accessed from the Options button in the Wind Tab
Binary Wind File Options dialog accessed from the Options button in the Wind Tab
  1. ^ a b Militello, A., and Zundel, A. K. (1999). “Surface-water modeling system tidal constituents toolbox for ADCIRC,” Coastal Engineering Technical Note CETN IV-21, U.S. Army Engineer Research and Development Center, Vicksburg, MS.
  2. ^ Le Provost, C., Genco, M. L., and Lyard, F. (1995). “Modeling and predicting tides over the World Ocean,” Quantitative Skill Assessment for Coastal Ocean Models, Coastal and Estuaring Studies, Vol. 47, pp 175-201.