Template:GMS MODFLOW 6 EVT Package Workflow: Difference between revisions

From XMS Wiki
Jump to navigationJump to search
(Created page with "{| class="mw-collapsible mw-collapsed" style="width:100%; border:1px solid #CDB7B5; margin-bottom:0.4em;" |- !style="text-align:left;"|1. Begin with an existing GMS:MODFLOW...")
 
m (Protected "Template:GMS MODFLOW 6 EVT Package Workflow" ([Edit=Allow only administrators] (indefinite) [Move=Allow only administrators] (indefinite)))
 
(2 intermediate revisions by one other user not shown)
Line 1: Line 1:
{| class="mw-collapsible mw-collapsed" style="width:100%; border:1px solid #CDB7B5; margin-bottom:0.4em;"
{| class="mw-collapsible mw-collapsed" style="width:100%; border:1px solid #CDB7B5; margin-bottom:0.4em;"  
|-
|-
!style="text-align:left;"|1. Begin with an existing [[GMS:MODFLOW 6|MODFLOW 6]] project.
!style="text-align:left;"|1. Begin with an existing [[GMS:MODFLOW 6|MODFLOW 6]] project.
Line 15: Line 15:
{| class="mw-collapsible mw-collapsed" style="width:100%; border:1px solid #CDB7B5; margin-bottom:0.4em;"
{| class="mw-collapsible mw-collapsed" style="width:100%; border:1px solid #CDB7B5; margin-bottom:0.4em;"
|-
|-
!style="text-align:left;"|3. Modify [[GMS:MF6 EVT Package|EVT]] inputs.
!style="text-align:left;"|3. Adjust the complexity settings for the IMS solver.
|-
|
:Sometimes the complexity settings on the IMS solver package need to be adjusted to handle the addition of the EVT package. If that is necessary, do so.
|}
{| class="mw-collapsible mw-collapsed" style="width:100%; border:1px solid #CDB7B5; margin-bottom:0.4em;"
|-
!style="text-align:left;"|4. Modify [[GMS:MF6 EVT Package|EVT]] inputs.
|-
|-
|
|
Line 23: Line 30:
:::*''RATE''
:::*''RATE''
:::*''DEPTH''
:::*''DEPTH''
:::If non-linear variation in the evapotranspiration rate is desired, also specify the following:
:::*The ''Number of ET segments'' in the ''DIMENSIONS'' section.
:::*''PXDP1''
:::*''PXDP2
:::*''PETM1''
:::*''PETM2''
|}<noinclude>[[Category:MODFLOW Workflow Templates|EVT, MODFLOW 6]]</noinclude>
|}<noinclude>[[Category:MODFLOW Workflow Templates|EVT, MODFLOW 6]]</noinclude>

Latest revision as of 21:11, 18 June 2024

1. Begin with an existing MODFLOW 6 project.
The existing MODFLOW 6 model can be created using the conceptual model or grid based approach.
2. Add the EVT package to the simulation.
  1. Right-click on the MF6 GWF Model.svg GWF model and select New Package, then select the desired package from the list.
3. Adjust the complexity settings for the IMS solver.
Sometimes the complexity settings on the IMS solver package need to be adjusted to handle the addition of the EVT package. If that is necessary, do so.
4. Modify EVT inputs.
  1. Right-click on the package in the Project Explorer and select the Open command.
  2. Modify the inputs in the package dialog.
These inputs include:
  • SURFACE
  • RATE
  • DEPTH
If non-linear variation in the evapotranspiration rate is desired, also specify the following:
  • The Number of ET segments in the DIMENSIONS section.
  • PXDP1
  • PXDP2
  • PETM1
  • PETM2