Line 20: Line 20:
|-
|-
|
|
:# Select the [[GMS:MODFLOW Commands|''MODFLOW'' | ''Advanced'' | '''Sources/Sinks...''']] menu command.
:# Select the [[GMS:MODFLOW Commands|''MODFLOW'' | ''Optional Packages'' | '''GNC – Ghost Node Correction Package''']] menu command.
:# Enter drain return values in the [[GMS:MODFLOW Source/Sink Dialog|''MODFLOW Sources/Sinks'']] dialog.
:# Compute ghost node correct data in the [[GMS:GNC Package|''GNC Package'']] dialog.
|}
|}
{| class="mw-collapsible mw-collapsed" style="width:80%; border:1px solid #CDB7B5; margin-bottom:0.4em;"
{| class="mw-collapsible mw-collapsed" style="width:80%; border:1px solid #CDB7B5; margin-bottom:0.4em;"

Revision as of 15:19, 1 August 2017

1. Begin with an existing MODFLOW-USG project.
The existing model can be created using the conceptual model or grid based approach.
2. Activate the ghost node correction package.
  1. Select MODFLOW | Global Options.
  2. In the MODFLOW Global/Basic Package dialog, select the Packages button.
  3. In the MODFLOW Packages/Processes dialog, select the GNC – Ghost Node Correction option.
3. Add GNC data.
  1. Select the MODFLOW | Optional Packages | GNC – Ghost Node Correction Package menu command.
  2. Compute ghost node correct data in the GNC Package dialog.
4. Run MODFLOW.
  1. Save Save Macro.svg the project.
  2. Run MODFLOW Run MODFLOW Macro.svg.