Template:GMS MODFLOW 6 EVT Package Workflow: Difference between revisions

From XMS Wiki
Jump to navigationJump to search
No edit summary
No edit summary
Line 15: Line 15:
{| class="mw-collapsible mw-collapsed" style="width:100%; border:1px solid #CDB7B5; margin-bottom:0.4em;"
{| class="mw-collapsible mw-collapsed" style="width:100%; border:1px solid #CDB7B5; margin-bottom:0.4em;"
|-
|-
!style="text-align:left;"| 3. Adjust the complexity settings for the IMS solver.
!style="text-align:left;"|3. Adjust the complexity settings for the IMS solver.
|-
|-
|
|
Line 22: Line 22:
{| class="mw-collapsible mw-collapsed" style="width:100%; border:1px solid #CDB7B5; margin-bottom:0.4em;"
{| class="mw-collapsible mw-collapsed" style="width:100%; border:1px solid #CDB7B5; margin-bottom:0.4em;"
|-
|-
!style="text-align:left;"|3. Modify [[GMS:MF6 EVT Package|EVT]] inputs.
!style="text-align:left;"|4. Modify [[GMS:MF6 EVT Package|EVT]] inputs.
|-
|-
|
|

Revision as of 16:42, 28 July 2022

1. Begin with an existing MODFLOW 6 project.
The existing MODFLOW 6 model can be created using the conceptual model or grid based approach.
2. Add the EVT package to the simulation.
  1. Right-click on the MF6 GWF Model.svg GWF model and select New Package, then select the desired package from the list.
3. Adjust the complexity settings for the IMS solver.
Sometimes the complexity settings on the IMS solver package need to be adjusted to handle the addition of the EVT package. If that is necessary, do so.
4. Modify EVT inputs.
  1. Right-click on the package in the Project Explorer and select the Open command.
  2. Modify the inputs in the package dialog.
These inputs include:
  • SURFACE
  • RATE
  • DEPTH
If non-linear variation in the evapotranspiration rate is desired, also specify the following:
  • The Number of ET segments in the DIMENSIONS section.
  • PXDP1
  • PXDP2
  • PETM1
  • PETM2