SMS:ADH Model Control Model Parameters

From XMS Wiki
Revision as of 21:28, 27 September 2007 by Kwinters (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigationJump to search

Go to ADH Model Control page

This page window is accessed from the Model Control window by clicking on the Model Parameters tab.

Dialog Description

The following controls specify how the ADH model will solve (operate and iterate through) the simulation.

Non-Linear Iterations

Maximum number of iterations per time step positive integer edit field provides the value for the IP NIT or IP FNI card.

Iteration tolerance positive real number edit field provides the value for the IP NTL card.

Reduce timestep / Accept solution radio group specifies with the inclusion of the IP NIT or IP FNI card respectively.

Increment tolerance check box and the associated Residual tolerance positive real number edit field correlates with the IP ITL card. The card is included in the simulation if this option is checked.

Linear Iterations By Solver

Maximum number of iterations positive integer edit field provides the value for the IP MIT or IP FLI card.

Stop the solution / Proceed to the next non-linear iteration radio group specifies with the inclusion of the IP MIT or IP FLI card respectively.

Operation

Incremental memory allocation block size check box with positive integer edit field correlates with the OP INC card.

Iterative solver pre-conditioner check box and the associated pre-conditioner combo-box and Block specification check box with positive integer edit field control group is tied to the OP PRE and OP BLK cards.

Include vessel movement library check box includes the OP BT card in the simulation when checked.


Go to ADH Model Control page