SMS:CMS-Flow Time Control: Difference between revisions
From XMS Wiki
Jump to navigationJump to search
No edit summary |
No edit summary |
||
Line 22: | Line 22: | ||
[[Category:CMS Dialogs|time]] | [[Category:CMS Dialogs|time]] | ||
[[Category:Archived CMS-Flow|time]] | [[Category:Archived CMS-Flow|time]] | ||
Revision as of 14:54, 24 August 2016
This contains information about features no longer in use for the current release of SMS. The content may not apply to current versions. |
The CMS-Flow Time Control dialog allows the user to specify the starting day and time for the simulation.
Other options include:
- Start Time – The hour at which to begin the model. This will be the first time step listed in any solution files.
- Simulation Duration – The length of the simulation in hours.
- Ramp Duration – The period of time in days at which to allow the model to “build up” or “ramp up” to a legitimate solution. Aids in the convergence of the model.
- Time Step Size – The time increment at which M2D makes internal calculations. Running the CMS-Flow Model Check from the CMS-Flow menu will provide an initial estimation for the maximum time step size that will produce a convergent result.
Retlated Topics
SMS – Surface-water Modeling System | ||
---|---|---|
Modules: | 1D Grid • Cartesian Grid • Curvilinear Grid • GIS • Map • Mesh • Particle • Quadtree • Raster • Scatter • UGrid | |
General Models: | 3D Structure • FVCOM • Generic • PTM | |
Coastal Models: | ADCIRC • BOUSS-2D • CGWAVE • CMS-Flow • CMS-Wave • GenCade • STWAVE • WAM | |
Riverine/Estuarine Models: | AdH • HEC-RAS • HYDRO AS-2D • RMA2 • RMA4 • SRH-2D • TUFLOW • TUFLOW FV | |
Aquaveo • SMS Tutorials • SMS Workflows |