BOUSS-2D makes use of the following files during a model run. | BOUSS-2D makes use of the following files during a model run. | ||
* Required files | * Required files | ||
** [[SMS:BOUSS-2D Parameter File|Parameter File]] (*.par) | |||
* [[SMS:BOUSS-2D Parameter File|Parameter File]] (*.par) | ** Bathymetry File (*_bathy.grd) | ||
* Bathymetry File (*_bathy.grd) | |||
* Optional files | * Optional files | ||
** Damping File (*_damping.grd) | |||
* Damping File (*_damping.grd) | ** Current File (*_current.grd) | ||
* Current File (*_current.grd) | ** Porosity File (*_porosity.grd) (Still under development – be advised to use with caution) | ||
* Porosity File (*_porosity.grd) (Still under development – be advised to use with caution) | ** Variable Roughness File (*_friction.grd) (Still under development – be advised to use with caution) | ||
* Variable Roughness File (*_friction.grd) (Still under development – be advised to use with caution) | |||
== Output Files == | == Output Files == |
Revision as of 16:09, 20 September 2017
BOUSS-2D makes use of input files during the model run and has options for outputting files.
Input Files
BOUSS-2D makes use of the following files during a model run.
- Required files
- Parameter File (*.par)
- Bathymetry File (*_bathy.grd)
- Optional files
- Damping File (*_damping.grd)
- Current File (*_current.grd)
- Porosity File (*_porosity.grd) (Still under development – be advised to use with caution)
- Variable Roughness File (*_friction.grd) (Still under development – be advised to use with caution)
Output Files
BOUSS-2D can output both spatial and locational files. Output file options are specified in the BOUSS-2D Model Control dialog.
- Spatial files – Values at every active computation point, These can be saved in 5 separate native BOUSS-2D formatted files (three ASCII and two binary) or in a single binary XMDF file (*.h5 – This is an HDF5 file). The native format files include:
- Transient datasets
- Water Surface File (*.eta) (This also includes breaking index at each cell.)
- Current File (*.uv)
- Mean values
- Significant Wave Height File (*_hs.grd)
- Mean Current File (*_mean_uv.grd)
- Mean Water Level File (*_mwl.grd)
- Locational files – These files contain information for specifaclly selected cells (probes)
- Water Level at Probes File (*_ts_eta.ts1)
- U Component of current at Probes File (*_ts_u.ts1)
- V Component of current at Probes File (*_ts_v.ts1)
- Pressure at Probes File (*_ts_p.ts1)
Related Topics
SMS – Surface-water Modeling System | ||
---|---|---|
Modules: | 1D Grid • Cartesian Grid • Curvilinear Grid • GIS • Map • Mesh • Particle • Quadtree • Raster • Scatter • UGrid | |
General Models: | 3D Structure • FVCOM • Generic • PTM | |
Coastal Models: | ADCIRC • BOUSS-2D • CGWAVE • CMS-Flow • CMS-Wave • GenCade • STWAVE • WAM | |
Riverine/Estuarine Models: | AdH • HEC-RAS • HYDRO AS-2D • RMA2 • RMA4 • SRH-2D • TUFLOW • TUFLOW FV | |