SMS:ADH Model Control Output: Difference between revisions
No edit summary |
|||
(17 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
{{ | __NOINDEX__ | ||
[[Image:ADH Model Control Output. | {{SMS Deprecated Feature}} | ||
[[Image:ADH Model Control Output.png|thumb|500 px| ''Output'' tab of the ''ADH Model Control'' dialog]] | |||
ADH output files are specified in the [[SMS:ADH Model Control|''ADH Model Control'']] dialog (''ADH'' | '''Model Control...''' command). It is accessed in the ''ADH Model Control'' window by clicking on the ''Output'' tab | |||
ADH will write solution data at startup and at each time step specified in a <font color="green">XY1</font> series definition and referred to by the <font color="green">OC</font> card. Flux data will be included with the solution data if output flow strings are specified (see [[ SMS:ADH Boundary Condition Assignment |assigning boundary conditions]]). | ADH will write solution data at startup and at each time step specified in a <font color="green">XY1</font> series definition and referred to by the <font color="green">OC</font> card. Flux data will be included with the solution data if output flow strings are specified (see [[ SMS:ADH Boundary Condition Assignment |assigning boundary conditions]]). | ||
The following controls specify how often solution data will be written by ADH and the number of flux boundaries present. | The following controls specify how often solution data will be written by ADH and the number of flux boundaries present. | ||
== Output Times == | |||
List box contains the times to be contained in the output series. Multiple selection is enabled for deleting times. | List box contains the times to be contained in the output series. Multiple selection is enabled for deleting times. | ||
''Add by specifying a range / Add individual output time'' radio group specifies time information to be added. | *''Add by specifying a range / Add individual output time'' radio group specifies time information to be added. The ''Add by specifying a range'' control group includes ''Start at'' positive integer/real number field and units combo box, ''End at'' positive integer/real number field, and ''Increment'' positive integer/real number field and units combo box. The ''End at'' time units are the same as specified for the ''Start at'' time. The ''Add individual output time'' control includes a positive integer/real number field and units combo box. Each edit field allows for positive integer seconds or positive real number minutes, hours, etc with six decimal places. All times are rounded to the nearest whole second (a decimal minute is rounded to the nearest decimal minute with a whole second equivalent) before being added. | ||
The ''Add by specifying a range'' control group includes ''Start at'' positive integer/real number field and units combo box, | |||
''End at'' positive integer/real number field, and ''Increment'' positive integer/real number field and units combo box. | |||
The ''End at'' time units are the same as specified for the ''Start at'' time. The ''Add individual output time'' control includes a positive integer/real number field and units combo box. Each edit field allows for positive integer seconds or positive real number minutes, hours, etc with six decimal places. All times are rounded to the nearest whole second (a decimal minute is rounded to the nearest decimal minute with a whole second equivalent) before being added. | |||
''Add'' button includes the time information from the above radio group in the times list box. Duplicate times will be automatically removed from the list. | *'''Add''' button includes the time information from the above radio group in the times list box. Duplicate times will be automatically removed from the list. | ||
''Delete'' button removes the selected time(s) from the list box. | *'''Delete''' button removes the selected time(s) from the list box. | ||
''Delete All'' buttons clears the entire times list without regard to the current selection. | *'''Delete All''' buttons clears the entire times list without regard to the current selection. | ||
''View output times in'' combo box specifies the time unit the list box will display the output times in. | *''View output times in'' combo box specifies the time unit the list box will display the output times in. | ||
''Specify curve fit tolerance'' check box and positive integer edit field specifies the series tolerance when checked. | *''Specify curve fit tolerance'' check box and positive integer edit field specifies the series tolerance when checked. | ||
== Flow == | |||
''Number of nodestrings specified to output flow calculated across themselves'' displays the total number of ADH flux boundaries included in the simulation. | ''Number of nodestrings specified to output flow calculated across themselves'' displays the total number of ADH flux boundaries included in the simulation. | ||
== Geometry == | |||
''Output adapted mesh files'' check box specifies whether geometry files will be saved as ADH adapts the mesh. The geometry will be outputted at the same interval specified in the list box for the solution data. This correlates to the <font color="green">PC ADP</font> card. | ''Output adapted mesh files'' check box specifies whether geometry files will be saved as ADH adapts the mesh. The geometry will be outputted at the same interval specified in the list box for the solution data. This correlates to the <font color="green">PC ADP</font> card. | ||
==Related Topics== | ==Related Topics== | ||
Line 39: | Line 35: | ||
*[[SMS:ADH Model Control | ADH Model Control]] | *[[SMS:ADH Model Control | ADH Model Control]] | ||
{{Template:Navbox SMS}} | |||
[[Category:ADH|M]] | |||
[[Category:SMS Model Control|A]] | |||
[[Category:ADH Dialogs|mod|out]] | |||
[[Category:Exporting Data|adh]] |
Latest revision as of 20:20, 11 September 2023
This contains information about features no longer in use for the current release of SMS. The content may not apply to current versions. |
ADH output files are specified in the ADH Model Control dialog (ADH | Model Control... command). It is accessed in the ADH Model Control window by clicking on the Output tab
ADH will write solution data at startup and at each time step specified in a XY1 series definition and referred to by the OC card. Flux data will be included with the solution data if output flow strings are specified (see assigning boundary conditions).
The following controls specify how often solution data will be written by ADH and the number of flux boundaries present.
Output Times
List box contains the times to be contained in the output series. Multiple selection is enabled for deleting times.
- Add by specifying a range / Add individual output time radio group specifies time information to be added. The Add by specifying a range control group includes Start at positive integer/real number field and units combo box, End at positive integer/real number field, and Increment positive integer/real number field and units combo box. The End at time units are the same as specified for the Start at time. The Add individual output time control includes a positive integer/real number field and units combo box. Each edit field allows for positive integer seconds or positive real number minutes, hours, etc with six decimal places. All times are rounded to the nearest whole second (a decimal minute is rounded to the nearest decimal minute with a whole second equivalent) before being added.
- Add button includes the time information from the above radio group in the times list box. Duplicate times will be automatically removed from the list.
- Delete button removes the selected time(s) from the list box.
- Delete All buttons clears the entire times list without regard to the current selection.
- View output times in combo box specifies the time unit the list box will display the output times in.
- Specify curve fit tolerance check box and positive integer edit field specifies the series tolerance when checked.
Flow
Number of nodestrings specified to output flow calculated across themselves displays the total number of ADH flux boundaries included in the simulation.
Geometry
Output adapted mesh files check box specifies whether geometry files will be saved as ADH adapts the mesh. The geometry will be outputted at the same interval specified in the list box for the solution data. This correlates to the PC ADP card.
Related Topics
SMS – Surface-water Modeling System | ||
---|---|---|
Modules: | 1D Grid • Cartesian Grid • Curvilinear Grid • GIS • Map • Mesh • Particle • Quadtree • Raster • Scatter • UGrid | |
General Models: | 3D Structure • FVCOM • Generic • PTM | |
Coastal Models: | ADCIRC • BOUSS-2D • CGWAVE • CMS-Flow • CMS-Wave • GenCade • STWAVE • WAM | |
Riverine/Estuarine Models: | AdH • HEC-RAS • HYDRO AS-2D • RMA2 • RMA4 • SRH-2D • TUFLOW • TUFLOW FV | |
Aquaveo • SMS Tutorials • SMS Workflows |