SMS:Create Spectral Energy Grid: Difference between revisions

From XMS Wiki
Jump to navigationJump to search
 
Line 19: Line 19:
** ''Minimum'' – Set the minimum frequency (Minimum = 0.04) in Hz.  
** ''Minimum'' – Set the minimum frequency (Minimum = 0.04) in Hz.  
** ''Maximum'' –  View the maximum frequency (Maximum = 0.33) in Hz.
** ''Maximum'' –  View the maximum frequency (Maximum = 0.33) in Hz.
* "Power series" –
* "Power series" – Select this to input step size in a power series.
** ''Mutiplier'' –
** ''Mutiplier'' – Set the multiplier for each step in Hz.
** ''Minimum'' –
** ''Minimum'' – Set the minimum frequency in Hz.
** ''Maximum'' –
** ''Maximum'' – Set the maximum frequency in Hz.


== Angle Distribution ==
== Angle Distribution ==

Latest revision as of 22:28, 29 May 2024

Create Spectral Energy Grid dialog

The Create Spectral Energy Grid dialog is accessed through the Spectral Energy dialog (by pushing the Create Grid button). Prior to reaching this dialog, the Spectral Grid Attributes dialog will appear. A spectral energy grid is created after setting the options. All units for the options are hertz and degrees. The new spectral energy grid will be displayed in the Spectral Manager and the Spectral Viewer in the Spectral Energy dialog.

Spectral Grid Attributes

The Spectral Grid Attributes dialog

This dialog is used to set the spectral grid parameters when creating a spectral energy grid. The dialog has the following options:

  • Grid angle – The angle of the grid can be altered if wanting the grid to vary from existing Cartesian grid.
  • Spectral energy grid plane type – Can be set to "Local" or "Global" to indicate which projection for the spectral energy grid to use.

Plane Type and Angle

  • Plane type (full global, full local, half local) – Sets the plane type for the spectral data
  • Angle – Sets the grid orientation

Frequency Distribution

  • Number – Set the number of frequency bands (Number = 30)
  • "Delta" – Select this to input step size in Delta.
    • Delta – Set the step size (Delta = 0.01) in Hz.
    • Minimum – Set the minimum frequency (Minimum = 0.04) in Hz.
    • Maximum – View the maximum frequency (Maximum = 0.33) in Hz.
  • "Power series" – Select this to input step size in a power series.
    • Mutiplier – Set the multiplier for each step in Hz.
    • Minimum – Set the minimum frequency in Hz.
    • Maximum – Set the maximum frequency in Hz.

Angle Distribution

  • Number – View the number of angle bands (Number = 35).
  • Delta – Set the step size (Delta = 5) in degrees.
  • Minimum – View the minimum angle (Minimum = 0.0) in degrees.
  • Maximum – View the maximum angle (Maximum = 360.0) in degrees.

Related Topics