GMS:SEAWAT MODFLOW AUX Variables: Difference between revisions

From XMS Wiki
Jump to navigationJump to search
No edit summary
No edit summary
Line 1: Line 1:
{{Infobox Model |
|name=          SEAWAT
|model_type=    3D Flow and Transport Model
|developer=    USGS
|documentation= [http://gmsdocs.aquaveo.com/seawatv4.pdf SEAWAT Manual]
|tutorials=    [[GMS:Tutorials#Models|SEAWAT Tutorials]]
}}
SEAWAT allows using MODFLOW AUX variables for some packages to set values used for MODFLOW packages the variables include:
SEAWAT allows using MODFLOW AUX variables for some packages to set values used for MODFLOW packages the variables include:
* WELDENS – Density of well fluid (WEL package).
* WELDENS – Density of well fluid (WEL package).

Revision as of 18:55, 27 March 2014

SEAWAT allows using MODFLOW AUX variables for some packages to set values used for MODFLOW packages the variables include:

  • WELDENS – Density of well fluid (WEL package).
  • DRNBELEV – Drain bottom elevation (DRN package).
  • RBDTHK – River bed thickness (RIV package).
  • RIVDEN – Density of river fluid (RIV package).
  • GHBELEV – General head elevation (GHB package).
  • GHBDENS – Density of general head fluid (GHB package).
  • CHDDENSOPT and CHDDEN – Constant head fluid density (CHD package).

These AUX variables can be enabled by selecting them in the SEAWAT Global Options dialog and can be edited in the associated MODFLOW Package dialog or in the MODFLOW Sources/Sinks dialog.