SMS:RMA4 Material Properties: Difference between revisions

From XMS Wiki
Jump to navigationJump to search
No edit summary
No edit summary
 
(20 intermediate revisions by the same user not shown)
Line 1: Line 1:
{{Hide in print|{{RMA4 Menubox}}
[[Image:RMA 4 MP.png|thumb|450 px|''RMA4 Material Properties'' dialog]]
}}
The ''RMA4 Material Properties'' dialog is reached through the ''RMA4'' | '''Material Properties...''' menu command in the Mesh module.
 
The dialog has the following options:
*Material list – a list of available materials is populated on the left side of the dialog. Selecting a material allows the diffusion to be changed for the material.
*''Overide global specification'' – When turned on the global diffusion will not be used for the material.
*''Diffusion coefficient method'' – Specifies using diffusion coefficients to approximate turbulence.
*''Peclet number method'' – Specifies the use of a Péclet number to determine diffusion.
*''Dx'' – Specifies diffusion in the x direction.
*''Dy'' – Specifies diffusion in the y direction.
*''Peclet Number'' – Enter the Péclet number value.
*''Minimum Velocity'' – The lowest velocity allowed for diffusion.
*'''General Material Properties''' – Brings up the ''Materials Data'' dialog.
 
==Diffusion==  
==Diffusion==  


Line 6: Line 18:




[[File:rma4 material properties.jpg|thumb|left|450 px|RMA4 Material Properties dialog]]
==Related Topics==
* [[SMS:RMA4|RMA4]]




{{Template:Navbox SMS}}
{{Template:Navbox SMS}}
[[Category:RMA4|M]]
[[Category:RMA4 Dialogs|mat]]
[[Category:SMS Materials|R]]

Latest revision as of 21:39, 12 June 2020

RMA4 Material Properties dialog

The RMA4 Material Properties dialog is reached through the RMA4 | Material Properties... menu command in the Mesh module.

The dialog has the following options:

  • Material list – a list of available materials is populated on the left side of the dialog. Selecting a material allows the diffusion to be changed for the material.
  • Overide global specification – When turned on the global diffusion will not be used for the material.
  • Diffusion coefficient method – Specifies using diffusion coefficients to approximate turbulence.
  • Peclet number method – Specifies the use of a Péclet number to determine diffusion.
  • Dx – Specifies diffusion in the x direction.
  • Dy – Specifies diffusion in the y direction.
  • Peclet Number – Enter the Péclet number value.
  • Minimum Velocity – The lowest velocity allowed for diffusion.
  • General Material Properties – Brings up the Materials Data dialog.

Diffusion

Because RMA4 does not have the ability to model turbulence, diffusion coefficients may be used to approximate turbulence. By assigning a diffusion coefficient in the x and y directions for each material, the flow over that material will be altered somewhat to provide an approximation of turbulent flow over that region. A value of -1.0 may be applied to allow normal flow over the material. Positive values provide turbulence. The higher the value, the greater the effect is.