SMS:Total Flow Nodestring: Difference between revisions

From XMS Wiki
Jump to navigationJump to search
No edit summary
No edit summary
Line 3: Line 3:
The nodestring assigned as total flow will always be reported first in the table, and will always have 100% of the flowrate across it. The flux across all other cross sections will be reported in the continuity table as a percentage of this flowrate, whether it be more, less, or equal to 100%. Note that nodestrings should all be created from right to left, while looking downstream. When a nodestring is selected, arrows appear on its ends which show the assumed downstream direction. The figures below show advisable locations of the total flow nodestring.
The nodestring assigned as total flow will always be reported first in the table, and will always have 100% of the flowrate across it. The flux across all other cross sections will be reported in the continuity table as a percentage of this flowrate, whether it be more, less, or equal to 100%. Note that nodestrings should all be created from right to left, while looking downstream. When a nodestring is selected, arrows appear on its ends which show the assumed downstream direction. The figures below show advisable locations of the total flow nodestring.


<gallery widths="400px" heights="300px">
<gallery widths="400px" heights="280px">
Image:TotalFlow1.png
Image:TotalFlow1.png
Image:TotalFlow2.png
Image:TotalFlow2.png

Revision as of 15:25, 13 October 2017

Two hydrodynamic models supported by SMS, RMA2 and FST2DH, support a concept called the Total Flow Nodestring. These models print out a table of continuity or flux checks across specified nodestrings. Such checks are used to determine if there is mass loss through the model, to determine the amount of flow in various sections of a braided stream, or other similar purpose. In order to participate in the continuity table, the nodestring must either be assigned as a boundary condition or assigned as a flux (FST2DH) or geometric continuity (GC) (RMA2) string.

The nodestring assigned as total flow will always be reported first in the table, and will always have 100% of the flowrate across it. The flux across all other cross sections will be reported in the continuity table as a percentage of this flowrate, whether it be more, less, or equal to 100%. Note that nodestrings should all be created from right to left, while looking downstream. When a nodestring is selected, arrows appear on its ends which show the assumed downstream direction. The figures below show advisable locations of the total flow nodestring.


Related Topics