SMS:SRH-2D Culvert Workflow: Difference between revisions

From XMS Wiki
Jump to navigationJump to search
No edit summary
No edit summary
Line 37: Line 37:
|-
|-
|width="800"|
|width="800"|
:# [[SMS:File Menu|Save]] the project.
{{SMS:SRH Run Simulation Workflow}}
:# [[SMS:Model Checker|Check the model]].
:# [[SMS:SRH Simulation#Running an SRH-2D Simulation|Simulation execution]].
:# [[SMS:SRH-2D#Troubleshooting|Troubleshooting]].
:See also: [[SMS:SRH Simulation Workflow|SRH Simulation Workflow]]
|}
|}
{|class="wikitable collapsible autocollapse"
{|class="wikitable collapsible autocollapse"

Revision as of 18:21, 18 August 2015

To build an SRH-2D model using a culvert, use the following steps:

2. Create culvert boundary conditions.
The culvert boundary conditions must be defined before running the simulation. To do this:
  1. Create a boundary conditions coverage.
  2. Create boundary condition arcs for the culvert.
  3. Specify the HY-8 culvert definition file.
  4. Assign the boundary condition attributes and define the culvert in HY-8.
  5. Modify the materials coverage.
3. Specify the simulation parameters.
The initial conditions of the stream must be defined in the simulation. To do this:
  1. Create new simulation.
  2. Add components to simulation.
  3. Set up the simulation Model Control parameters.
  4. Specify the restart conditions file under initial conditions.
See also: SRH Simulation Workflow
4. Run the SRH-2D simulation.

SMS:SRH Run Simulation Workflow

5. Review results.
Results for the culvert simlation can be viewed by doing the following:
  1. Load solution datasets.
  2. Run the data calculator.