SMS:Create Spectral Energy Grid: Difference between revisions

From XMS Wiki
Jump to navigationJump to search
Line 21: Line 21:
== Angle Distribution ==
== Angle Distribution ==


* '''Number''' – View the number of angle bands (Number = 35).
* ''Number'' – View the number of angle bands (Number = 35).
* '''Delta''' – Set the  step size (Delta = 5) in degrees.
* ''Delta'' – Set the  step size (Delta = 5) in degrees.
* '''Minimum''' – View the minimum angle (Minimum = 0.0) in degrees.  
* ''Minimum'' – View the minimum angle (Minimum = 0.0) in degrees.  
* '''Maximum''' – View the maximum angle (Maximum = 360.0) in degrees.
* ''Maximum'' – View the maximum angle (Maximum = 360.0) in degrees.
 


==Related Topics==
==Related Topics==

Revision as of 14:42, 17 July 2017

Create Spectral Energy Grid dialog

The Create Spectral Energy Grid dialog is accessed through the Spectral Energy dialog (by pushing the Create Grid button). Prior to reaching this dialog, the Spectral Grid Attributes dialog will appear. A spectral energy grid is created after setting the options. All units for the options are hertz and degrees. The new spectral energy grid will be displayed in the Spectral Manager and the Spectral Viewer in the Spectral Energy dialog.'

Spectral Grid Attributes

The Spectral Grid Attributes dialog

This dialog is used to set the spectral grid parameters when creating a spectral energy grid. The dialog has the following options:

  • Grid angle – The angle of the grid can be altered if wanting the grid to vary from existing Cartesian grid.
  • Spectral energy grid plane type – Can be set to "Local" or "Global" to indicate which projection for the spectral energy grid to use.

Plane Type and Angle

  • Plane type (full global, full local, half local) – Sets the plane type for the spectral data
  • Angle – Sets the grid orientation

Frequency Distribution

  • Number – Set the number of frequency bands (Number = 30)
  • Delta – Set the step size (Delta = 0.01) in Hz.
  • Minimum – Set the minimum frequency (Minimum = 0.04) in Hz.
  • Maximum – View the maximum frequency (Maximum = 0.33) in Hz.

Angle Distribution

  • Number – View the number of angle bands (Number = 35).
  • Delta – Set the step size (Delta = 5) in degrees.
  • Minimum – View the minimum angle (Minimum = 0.0) in degrees.
  • Maximum – View the maximum angle (Maximum = 360.0) in degrees.

Related Topics