GMS:PCB Package: Difference between revisions
From XMS Wiki
Jump to navigationJump to search
No edit summary |
No edit summary |
||
Line 4: | Line 4: | ||
The Prescribed Concentration Boundary (PCB) package is only used when there is a constant concentration boundary condition in the MODFLOW-USG Transport simulation. | The Prescribed Concentration Boundary (PCB) package is only used when there is a constant concentration boundary condition in the MODFLOW-USG Transport simulation. | ||
A constant concentration boundary condition can be assigned to a the MODFLOW-USG Tranport model by using the ''MODFLOW/MT3DMS Source/Sinks'' dialog for either selected cells or in the conceptual model. | A constant concentration boundary condition can be assigned to a the MODFLOW-USG Tranport model by using the [[GMS:MODFLOW Source/Sink Dialog|''MODFLOW/MT3DMS Source/Sinks'']] dialog for either selected cells or in the conceptual model. | ||
In the ''MODFLOW Prescribed Concentration Boundary (PCB) Package'' dialog, the following can be edited: | In the ''MODFLOW Prescribed Concentration Boundary (PCB) Package'' dialog, the following can be edited: |
Revision as of 19:52, 21 August 2018
This contains information about functionality available starting at GMS version 10.4. The content may not apply to other versions. |
The Prescribed Concentration Boundary (PCB) package is only used when there is a constant concentration boundary condition in the MODFLOW-USG Transport simulation.
A constant concentration boundary condition can be assigned to a the MODFLOW-USG Tranport model by using the MODFLOW/MT3DMS Source/Sinks dialog for either selected cells or in the conceptual model.
In the MODFLOW Prescribed Concentration Boundary (PCB) Package dialog, the following can be edited:
- Stress period
- Use previous
- Edit All Use Previous
- cell ID – Changing the cell ID will change which cell contains the concentration boundary.
- Species ID – List which species has been assigned to the cell. Will only accept values corresponding to existing species as defined in the BCT Process.
- Concentration – The concentration value assigned to the cell.
GMS – Groundwater Modeling System | ||
---|---|---|
Modules: | 2D Grid • 2D Mesh • 2D Scatter Point • 3D Grid • 3D Mesh • 3D Scatter Point • Boreholes • GIS • Map • Solid • TINs • UGrids | |
Models: | FEFLOW • FEMWATER • HydroGeoSphere • MODAEM • MODFLOW • MODPATH • mod-PATH3DU • MT3DMS • MT3D-USGS • PEST • PHT3D • RT3D • SEAM3D • SEAWAT • SEEP2D • T-PROGS • ZONEBUDGET | |
Aquaveo |