Line 18: Line 18:
**''PRINT_FLOWS'' – If turned on, indicates that a list of multi-aquifer well flow rates will be printed to the listing file.
**''PRINT_FLOWS'' – If turned on, indicates that a list of multi-aquifer well flow rates will be printed to the listing file.
**''SAVE_FLOWS'' – If turned on, indicates that the multi-aquifer well flow terms will be written to a specified file.
**''SAVE_FLOWS'' – If turned on, indicates that the multi-aquifer well flow terms will be written to a specified file.
**''HEAD FILEOUT'' – The name of the output file to write stage information.
**''HEAD_FILEOUT'' – The name of the output file to write stage information.
**''BUDGET FILEOUT'' – Allows the specification of a file to which desired flow terms will be written.
**''BUDGET_FILEOUT'' – Allows the specification of a file to which desired flow terms will be written.
**''NO_WELL_STORAGE'' – If turned on, indicates that well storage will not be included in the continuity equation. It is used to control discharge rate oscillations.
**''NO_WELL_STORAGE'' – If turned on, indicates that well storage will not be included in the continuity equation. It is used to control discharge rate oscillations.
**''FLOWING_WELLS'' – If turned on, indicates that the flowing wells option is activated.
**''FLOWING_WELLS'' – If turned on, indicates that the flowing wells option is activated.
Line 36: Line 36:
**'''Open Time Series''' [[File:Open Macro.svg|14px]] – Click to bring up the  
**'''Open Time Series''' [[File:Open Macro.svg|14px]] – Click to bring up the  
**'''Filter on Selected Cells''' [[File:Mf6filter.svg|14px]] – Click to turn on filtering on the selected cells.
**'''Filter on Selected Cells''' [[File:Mf6filter.svg|14px]] – Click to turn on filtering on the selected cells.
*''Table'' – Allows the manual input of different variables for the MAW Package.
***Table – Allows the manual input of different variables for the MAW Package.
**'''WELLNO''' – A value that defines the reach number associated with the specified PERIOD data.
****''WELLNO'' – A value that defines the reach number associated with the specified PERIOD data.
**'''MAWSETTING''' – Information that is linked to keywords and values.
****''MAWSETTING'' – Information that is linked to keywords and values.
**'''VALUE1''' – Value to be entered in relation to the specific project.
****''VALUE1'' – Value to be entered in relation to the specific project.
**'''VALUE2''' – Value to be entered in relation to the specific project.
****''VALUE2'' – Value to be entered in relation to the specific project.
**'''VALUE3''' – Value to be entered in relation to the specific project.
****''VALUE3'' – Value to be entered in relation to the specific project.





Revision as of 20:58, 12 February 2020

The Multi-Aquifer Well (MAW) Package dialog

The Multi-Aquifer Well (MAW) Package dialog is accessed by double-clicking on the WEL package under a MODFLOW 6 simulation in the Project Explorer. It contains the following sections and options:

  • Sections list – A list of sections that can be turned on or off:
    • Comments – Turn on to make the Comments section visible.
    • Options – Turn on to make the Options section visible.
    • Data – Turn on to make the Data section visible. This section is on by default.
  • Comments section – Enter general alphanumeric comments. Comments entered here get written at the top of the file, preceded by a '#' symbol.
  • Options section – Temporal options and settings:
  • Options section – Temporal options and settings:
    • BOUNDNAMES – If turned on, indicates that the list of multi-aquifer well cells will be provided with the associative boundary names.
    • PRINT_INPUT – If turned on, indicates that the list of multi-aquifer well information will be written to the listing file after it is read.
    • PRINT_HEAD – If turned on, indicates that well heads will be printed to the listing file for each stress period that "HEAD PRINT" is specified.
    • PRINT_FLOWS – If turned on, indicates that a list of multi-aquifer well flow rates will be printed to the listing file.
    • SAVE_FLOWS – If turned on, indicates that the multi-aquifer well flow terms will be written to a specified file.
    • HEAD_FILEOUT – The name of the output file to write stage information.
    • BUDGET_FILEOUT – Allows the specification of a file to which desired flow terms will be written.
    • NO_WELL_STORAGE – If turned on, indicates that well storage will not be included in the continuity equation. It is used to control discharge rate oscillations.
    • FLOWING_WELLS – If turned on, indicates that the flowing wells option is activated.
    • SHUTDOWN_THETA – Defines the weight that is applied to the discharge rate for wells that have water limitations.
    • SHUTDOWN_KAPPA – Defines the weight that is applied to the discharge rate for wells that have water limitations. It is used to control discharge rate oscillations.
    • MOVER – When turned on, indicates that the Unsaturated Zone Flow (SFR) Package, in this instance can be used in collaboration with the Water Mover (MVR) Package.
  • Data section – Contains the following:
    • Periods drop-down – Use the Increment Up and Down Increment up and down arrows.png buttons to select the desired period.
    • Define Period Add Note Icon.svg – If no period is defined, click to make the spreadsheet editable.
    • Delete Period GMS Delete Icon.svg – Click to delete the existing period.
    • Add Rows Row-add.svg – Click to bring up the Add Stresses dialog.
    • Delete Rows Row-delete.svg – Click to bring up a dialog with three options:
      • Delete from All Periods – Click to delete matching stresses from all periods.
      • Delete from Just This Period – Click to delete matching stresses from just this period.
    • Plot All Periods Mf6time-series.svg – Click to bring up the XY Series Editor dialog. Requires that a cell be selected in the table.
    • Open Time Series Open Macro.svg – Click to bring up the
    • Filter on Selected Cells Mf6filter.svg – Click to turn on filtering on the selected cells.
      • Table – Allows the manual input of different variables for the MAW Package.
        • WELLNO – A value that defines the reach number associated with the specified PERIOD data.
        • MAWSETTING – Information that is linked to keywords and values.
        • VALUE1 – Value to be entered in relation to the specific project.
        • VALUE2 – Value to be entered in relation to the specific project.
        • VALUE3 – Value to be entered in relation to the specific project.