SMS:RMA4 BC Elements: Difference between revisions

From XMS Wiki
Jump to navigationJump to search
(No difference)

Revision as of 16:00, 3 June 2009

A boundary mass loading can be added to an element in the mesh by selecting first the desired element and then the RMA4 | Assign BC menu command. This opens the RMA4 Assign Element Mass Loading dialog where a constant or transient entry can be made in grams/second for each constituent defined in the RMA4 model control dialog. The time variant option uses a XY Series File, XYS Format editor to enter a series of time step-mass loading pairs. The time steps should be consistent with those of the RMA4 simulation and for each constituent. The mass loadings may be deleted using the RMA4/Delete BC menu command.

Card Type RMA4 BLE Card: Boundary Loading (Mass)
Description Used to assign mass loading on the element boundary.
Required NO
Format BLE
Sample BLE 237 2 3
Field Variable Value Description
0 IC1 BLE Card type identifier.
1 ISTART + Element id
2 PBCX(J,1) + Mass loading for constituent 1 at ISTART=J (g/s)
3 PBCX(J,2) + Mass loading for constituent 2 at ISTART=J (g/s)
4 PBCX(J,3) + Mass loading for constituent 3 at ISTART=J (g/s)
5 PBCX(J,4) + Mass loading for constituent 4 at ISTART=J (g/s)
6 PBCX(J,5) + Mass loading for constituent 5 at ISTART=J (g/s)
7 PBCX(J,6) + Mass loading for constituent 6 at ISTART=J (g/s)


Card Type END
Description Identifies the end of the time step
Required NO


Related Topics