SMS:RMA2 Boundary Conditions

From XMS Wiki
Jump to navigationJump to search

Assigning Boundary Conditions

Boundary conditions are generally defined on nodestrings but may also be defined on nodes. The default boundary condition is a closed boundary (no flow).

Deleting Boundary Conditions

Nodal Boundary Conditions

NodeBC.JPG

Boundary Condition Type

  • None
    No Boundary Condition is assigned to this Nodestring
  • Water Surface Elevation
    A Water surface elevation BC is assigned to this Nodestring. This boundary condition is normally located at the tailwater location. (However RMA2 does sometime edit the water depth at the exit boundary to satisfy the finite element equations)
  • Velocity Components
  • Unit Flowrate
  • No Slip Condition

Boundary Angle

  • Specify Flow Direction
    • Perpendicular into Boundary
    • Perpendicular out of Boundary
    • Specified angle

Optional Parameters

  • Water Density
  • Include in node summary file

Boundary Condition Value

  • Constant
  • Transient

Nodestring Boundary Conditions

See RMA2 Boundary Condition Nodestrings for more information.