SEAWAT allows using MODFLOW AUX variables for some packages to set values used for MODFLOW packages the variables include:

  • WELDENS – Density of well fluid (WEL package).
  • DRNBELEV – Drain bottom elevation (DRN package).
  • RBDTHK – River bed thickness (RIV package).
  • RIVDEN – Density of river fluid (RIV package).
  • GHBELEV – General head elevation (GHB package).
  • GHBDENS – Density of general head fluid (GHB package).
  • CHDDENSOPT and CHDDEN – Constant head fluid density (CHD package).