GMS:File Import Wizard Supported File Formats: Difference between revisions

From XMS Wiki
Jump to navigationJump to search
Line 19: Line 19:
|}
|}


===Examples===
{|
|-
|
{|class="wikitable"
{|class="wikitable"
|+<center>'''EXAMPLES'''</center>
!"id"
!"id"
!"x"
!"x"
Line 33: Line 37:
|-
|-
|"OW-23"||83.3||8438.2||89||47||52
|"OW-23"||83.3||8438.2||89||47||52
|-
|"OW-24"||46.8||7829.1||207||147||134
|}
|
<pre>
"id" "x" "y" "xylene" "toluene 0.0" "toluene 2.0"
"OW-21" 32.4 5234.3 300 999 999
"OW-22" 93.4 5832.3 84 398 401
"OW-23" 83.3 8438.2 89 47 52
"OW-24" 46.8 7829.1 207 147 134
</pre>
|}
|}


Line 51: Line 66:
|-
|-
|"OW-23"||83.3||8438.2||89||93||93
|"OW-23"||83.3||8438.2||89||93||93
|-
|"OW-24"||46.8||7829.1||207||147||134
|}
|}
|
|

Revision as of 20:06, 6 December 2011

The Text Import Wizard can import various types of data as described in the tables below.

2D scatter points

This will create new scatter points in a new 2D scatter set. Optionally the imported points can be filtered using the filter options available by selecting the Filter Options button.

Field Type Required Comments
X
Number
yes
Y
Number
yes
Label
Text
no
Data Set
Number
no
Any number of steady-state or transient data sets can be imported. When importing transient data sets, a data set name and a time step must be specified for each transient column. Names and time steps are entered into the header row, separated by a vertical slash using the following format: "Name|Timestep". For example, "Dataset1|January 1, 1900". All time steps of a transient data set should be given the same name.

Examples

"id" "x" "y" "xylene" "toluene 0.0" "toluene 2.0"
"OW-21" 32.4 5234.3 300 999 999
"OW-22" 93.4 5832.3 84 398 401
"OW-23" 83.3 8438.2 89 47 52
"OW-24" 46.8 7829.1 207 147 134
"id"	"x"	"y"	"xylene"	"toluene 0.0"	"toluene 2.0"
"OW-21"	32.4	5234.3	300	999	999
"OW-22"	93.4	5832.3	84	398	401
"OW-23"	83.3	8438.2	89	47	52
"OW-24"	46.8	7829.1	207	147	134
"id" "x" "y" "xylene|01/01/2000 00:00" "xylene|01/01/2000 12:00" "xylene|01/02/2000 00:00"
"OW-21" 32.4 5234.3 300 310 312
"OW-22" 93.4 5832.3 84 87 93
"OW-23" 83.3 8438.2 89 93 93
"OW-24" 46.8 7829.1 207 147 134
"id"	"x"	"y"	"xylene|01/01/2000 00:00"	"xylene|01/01/2000 12:00"	"xylene|01/02/2000 00:00"
"OW-21"	32.4	5234.3	300	310	312
"OW-22"	93.4	5832.3	84	87	93
"OW-23"	83.3	8438.2	89	93	93
"OW-24"	46.8	7829.1	207	147	134

3D scatter points

This will create new scatter points in a new 3D scatter set.

Field Type Required Comments
X
Number
yes
Y
Number
yes
Z
Number
yes
Label
Text
no
Material ID
Number
no
Data Set
Number
no
Any number of steady-state or transient data sets can be imported. When importing transient data sets, a data set name and a time step must be specified for each transient column. Names and time steps are entered into the header row, separated by a vertical slash using the following format: "Name|Timestep". For example, "Dataset1|January 1, 1900". All time steps of a transient data set should be given the same name.
EXAMPLES
"id" "x" "y" "z" "xylene" "toluene 0.0" "toluene 2.0"
"OW-21" 32.4 5234.3 10.1 300 999 999
"0W-22" 93.4 5832.3 25.7 84 398 401
"0W-23" 83.3 8438.2 5.3 89 47 52
"id" "x" "y" "z" "xylene|01/01/2000 00:00" "xylene|01/01/2000 12:00" "xylene|01/02/2000 00:00"
"OW-21" 32.4 5234.3 10.1 300 310 312
"OW-22" 93.4 5832.3 25.7 84 87 93
"OW-23" 83.3 8438.2 5.3 89 93 93

Observation data

This creates new feature points in the existing, active coverage. The active coverage must exist and have a steady state observation attribute (like "Head") defined.

Field Type Required Comments
Point Name
Text
no
X
Number
yes
Y
Number
yes
Z
Number
no
Layer
Number
no
The 3D grid layer the point is associated with.
Measurement
Text
no
Measurement name. Multiple measurements allowed.
Interval
Number
no
Use Interval and Confidence, or Std. Dev. but not both.
Confidence
Number
no
Use Interval and Confidence, or Std. Dev. but not both.
Standard Deviation
Number
no
Use Interval and Confidence, or Std. Dev. but not both.
EXAMPLE
"name" "x" "y" "z" "lay" "hd" "int" "conf"
"OBS_Q5" 23.3 44.2 32.2 1 567.5 1.2 95
"OBS_Q6" 83.3 84.3 32.2 1 555.3 1.4 90
"OBS_Q7" 85.3 39.3 33.2 1 999 0 0

Transient observation data

This adds time series curves to existing points in an existing observation coverage. The targeted coverage must be the active coverage. The existing points and the data being imported are matched by name.

Field Type Required Comments
Point Name
Text
yes
Date (MM/DD/YYYY)
Date
yes
Time (HH:MM:SS)
Time
yes
EXAMPLE
"name" "date" "time" "head"
"OBS_Q5" 12/3/1999 18:00:00 238.5
"OBS_Q5" 1/30/2000 7:38:25 834.7
"OBS_Q6" 3/27/2000 18:00:00 878.3
"OBS_Q6" 12/3/1999 18:00:00 733.2

Well data

This creates new feature points in an existing coverage. The point types are set to "well" and the flow rate and other data are assigned to the points. A coverage with the "Wells" attribute must already exist and be the active coverage.

Field Type Required Comments
Name
Text
no
X
Number
yes
Y
Number
yes
Z
Number
no
Elevation of top of well.
Depth
Number
no
Depth to top of screen.
Screen Length
Number
no
Flow Rate
Number
no
Positive for injection, negative for extraction.
EXAMPLE
"name" "x" "y" "z" "depth" "len" "Q"
"well_1" 123.5 843.2 62.0 51.4 6.0 120.5
"well_2" 134.2 789.4 62.8 60.7 5.4 100.3
"well_3" 147.2 678.1 61.4 110 10.0 300.5

Pumping data

This adds time series curves to existing points in an existing coverage containing wells. The targeted coverage must be the active coverage. The existing points and the data being imported are matched by name.

Field Type Required Comments
Well Name
Text
yes
Must match an existing well, or else data is ignored.
Date(MM/DD/YYYY)
Number
yes
Time(HH:MM:SS)
Number
yes
Flow Rate
Number
yes
Depth
Number
no
Depth to top of screen.
Screen Length
Number
no
Flow Rate
Number
no
Positive for injection, negative for extraction.
EXAMPLE
"name" "date" "time" "Q"
"well_1" 12/3/1999 18:00:00 625.0
"well_1" 1/30/2000 7:38:25 0
"well_2" 13/3/1999 18:00:00 0
"well_2" 15/5/1999 14:48:32 100.0

Borehole data

This creates new boreholes. Optionally, a borehole folder name can be specified to organize the imported boreholes.

Field Type Required Comments
Borehole Name
Text
yes
X
Number
yes
X location of the contact.
Y
Number
yes
Y location of the contact.
Z
Number
yes
Z location of the contact.
HGU ID
Number
yes
HGU Material below the contact
Material ID
Number
no
Material below the contact.
Horizon ID
Number
no
EXAMPLE
"name" "x" "y" "z" "material" "horizon"
"borehole_1" 0.0 0.0 0.0 3 1
"borehole_1" 0.0 0.0 10.0 1 2
"borehole_1" 0.0 0.0 15.0 6 4
"borehole_2" 5.0 0.0 1.0 2 3
"borehole_2" 5.0 0.0 6.0 2 4

Borehole sample data

This creates new sample data on existing boreholes, or new sample data on new boreholes if no boreholes with matching names exist. All existing sample data is replaced with that being imported.

Field Type Required Comments
Name
Text
yes
New Borehole Name
X
Number
yes
X location of the borehole.
Y
Number
yes
Y location of the borehole.
Z
Number
yes
Z location of the borehole.
Data Set
Number
yes
EXAMPLE
"name" "x" "y" "z" "data"
"borehole_1" 0.0 0.0 0.0 495
"borehole_1" 0.0 0.0 10.0 484
"borehole_1" 0.0 0.0 15.0 454
"borehole_2" 5.0 0.0 1.0 259
"borehole_2" 5.0 0.0 6.0 248

Transient point data

This creates new time series curve data on existing feature points similar to the Pumping data option above. This option is more generic than the Pumping data option, however, because it will work with feature points of any type and any attribute (that can be transient) of that feature point. The imported data is matched to the existing points by name or by XY location. Data for more than one attribute can be imported at the same time. The attributes of the active coverage are listed as available fields that can be mapped.

Field Type Required Comments
Name
Text
no
Either this or X and Y must be mapped.
Date (MM/DD/YYYY)
Date
yes
Time (HH:MM:SS)
Time
yes
X
Number
no
Either this or Name must be mapped.
Y
Number
no
Either this or Name must be mapped.
[Attribute1...]
Number
No
The value of the selected attribute at the given date/time.
[AttributeN]
Number
No
The value of the selected attribute at the given date/time.
EXAMPLE
"name" "date" "time" "X" "Y" "Flow rate"
"well_1" 12/3/1999 18:00:00 123.5 843.2 625
"well_1" 1/30/2000 7:38:25 123.5 843.2 0
"well_2" 3/27/2000 18:00:00 134.2 789.4 0
"well_2" 12/3/1999 18:00:00 134.2 789.4 100.0

Transient node data

Similar to Transient point data but for nodes. Since nodes don't have names they must be matched by XY location.

Field Type Required Comments
Date (MM/DD/YYYY)
Date
yes
Time (HH:MM:SS)
Time
yes
X
Number
yes
Y
Number
yes
[Attribute1...]
Number
No
The value of the selected attribute at the given date/time.
[AttributeN]
Number
No
The value of the selected attribute at the given date/time.

Transient arc data

Similar to Transient point data but for arcs. Since arcs don't have a single XY location they must be matched by name.

Field Type Required Comments
Name
Text
yes
Date (MM/DD/YYYY)
Date
yes
Time (HH:MM:SS)
Time
yes
[Attribute1...]
Number
No
The value of the selected attribute at the given date/time.
[AttributeN]
Number
No
The value of the selected attribute at the given date/time.

Transient polygon data

Similar to Transient point data but for polygons. Since polygons don't have a single XY location they must be matched by name.

Field Type Required Comments
Name
Text
yes
Date (MM/DD/YYYY)
Date
yes
Time (HH:MM:SS)
Time
yes
[Attribute1...]
Number
No
The value of the selected attribute at the given date/time.
[AttributeN]
Number
No
The value of the selected attribute at the given date/time.