A boundary mass loading can be added to an element in the mesh by selecting first the desired element and then the [[SMS:RMA4 Menu|RMA4 | Assign BC]] menu command. This opens the RMA4 Assign Element Mass Loading dialog where a constant or transient entry can be made in grams/second for each constituent defined in the [[SMS:RMA4 Model Control|RMA4 model control dialog]]. The time variant option uses a [[SMS:XY_Series_Files_%28%2A.xys%29|XY Series File, XYS Format]] editor to enter a series of time step-mass loading pairs. The time steps should be consistent with those of the RMA4 simulation and for each constituent. The mass loadings may be deleted using the RMA4/Delete BC menu command. | A boundary mass loading can be added to an element in the mesh by selecting first the desired element and then the [[SMS:RMA4 Menu|RMA4 | Assign BC]] menu command. This opens the RMA4 Assign Element Mass Loading dialog where a constant or transient entry can be made in grams/second for each constituent defined in the [[SMS:RMA4 Model Control|RMA4 model control dialog]]. The time variant option uses a [[SMS:XY_Series_Files_%28%2A.xys%29|XY Series File, XYS Format]] editor to enter a series of time step-mass loading pairs. The time steps should be consistent with those of the RMA4 simulation and for each constituent. The mass loadings may be deleted using the RMA4/Delete BC menu command. | ||
Revision as of 18:25, 20 November 2012
RMA4 Pages |
---|
TABS – RMA2/RMA4 |
GFGEN Pages
|
RMA4
|
Aquaveo |
A boundary mass loading can be added to an element in the mesh by selecting first the desired element and then the RMA4 | Assign BC menu command. This opens the RMA4 Assign Element Mass Loading dialog where a constant or transient entry can be made in grams/second for each constituent defined in the RMA4 model control dialog. The time variant option uses a XY Series File, XYS Format editor to enter a series of time step-mass loading pairs. The time steps should be consistent with those of the RMA4 simulation and for each constituent. The mass loadings may be deleted using the RMA4/Delete BC menu command.
Card Type | RMA4 BLE Card: Boundary Loading (Mass) | ||
---|---|---|---|
Description | Used to assign mass loading on the element boundary. | ||
Required | NO | ||
Format | BLE | ||
Sample | BLE 237 2 3 | ||
Field | Variable | Value | Description |
0 | IC1 | BLE | Card type identifier. |
1 | ISTART | + | Element id |
2 | PBCX(J,1) | + | Mass loading for constituent 1 at ISTART=J (g/s) |
3 | PBCX(J,2) | + | Mass loading for constituent 2 at ISTART=J (g/s) |
4 | PBCX(J,3) | + | Mass loading for constituent 3 at ISTART=J (g/s) |
5 | PBCX(J,4) | + | Mass loading for constituent 4 at ISTART=J (g/s) |
6 | PBCX(J,5) | + | Mass loading for constituent 5 at ISTART=J (g/s) |
7 | PBCX(J,6) | + | Mass loading for constituent 6 at ISTART=J (g/s) |
Card Type | END | ||
---|---|---|---|
Description | Identifies the end of the time step | ||
Required | NO |
Related Topics
SMS – Surface-water Modeling System | ||
---|---|---|
Modules: | 1D Grid • Cartesian Grid • Curvilinear Grid • GIS • Map • Mesh • Particle • Quadtree • Raster • Scatter • UGrid | |
General Models: | 3D Structure • FVCOM • Generic • PTM | |
Coastal Models: | ADCIRC • BOUSS-2D • CGWAVE • CMS-Flow • CMS-Wave • GenCade • STWAVE • WAM | |
Riverine/Estuarine Models: | AdH • HEC-RAS • HYDRO AS-2D • RMA2 • RMA4 • SRH-2D • TUFLOW • TUFLOW FV | |
Aquaveo • SMS Tutorials • SMS Workflows |