Once a [[GMS:3D Grid Module#Creating 3D Grids|grid has been created]], the next step in converting a [[GMS:MODFLOW Conceptual Model Approach|MODFLOW conceptual model]] to a [[GMS:3D Grid Module|numerical model]] is to inactivate the cells which lie outside the boundary of the conceptual model. This is accomplished by selecting the | Once a [[GMS:3D Grid Module#Creating 3D Grids|grid has been created]], the next step in converting a [[GMS:MODFLOW Conceptual Model Approach|MODFLOW conceptual model]] to a [[GMS:3D Grid Module|numerical model]] is to inactivate the cells which lie outside the boundary of the conceptual model. This is accomplished by selecting the '''Activate Cells in Coverage''' command in the ''Feature Objects'' menu. When this command is selected, GMS utilizes the polygons in the coverage that is designated as the model boundary to determine which cells should be active and which cells should be inactive. Each cell is compared with the polygons in the coverage and if the cell does not lie within the interior of any of the polygons, the cell is determined to be outside the domain of the model and is inactivated. Cells inside the model domain are made active. | ||
{{hide in print|[[Image:Activate1.gif|right|frame|Sample Application of the Activate Cells in Coverage Command]]}} | {{hide in print|[[Image:Activate1.gif|right|frame|Sample Application of the '''Activate Cells in Coverage''' Command]]}} | ||
{{only in print|[[Image:Activate1.gif|right|frame|Sample Application of the Activate Cells in Coverage Command|250px]]}} | {{only in print|[[Image:Activate1.gif|right|frame|Sample Application of the '''Activate Cells in Coverage''' Command|250px]]}} | ||
When cells are tested to determine whether they are outside or inside the model domain, if the cell lies partially inside the model domain and partially out, the attribute type of the [[GMS:Feature Objects|feature object]] on the boundary where the cell is located is used to determine the active/inactive status of the cell. An example of this process is shown in the figure at the right. | When cells are tested to determine whether they are outside or inside the model domain, if the cell lies partially inside the model domain and partially out, the attribute type of the [[GMS:Feature Objects|feature object]] on the boundary where the cell is located is used to determine the active/inactive status of the cell. An example of this process is shown in the figure at the right. | ||
Revision as of 16:30, 18 July 2014
Once a grid has been created, the next step in converting a MODFLOW conceptual model to a numerical model is to inactivate the cells which lie outside the boundary of the conceptual model. This is accomplished by selecting the Activate Cells in Coverage command in the Feature Objects menu. When this command is selected, GMS utilizes the polygons in the coverage that is designated as the model boundary to determine which cells should be active and which cells should be inactive. Each cell is compared with the polygons in the coverage and if the cell does not lie within the interior of any of the polygons, the cell is determined to be outside the domain of the model and is inactivated. Cells inside the model domain are made active.
When cells are tested to determine whether they are outside or inside the model domain, if the cell lies partially inside the model domain and partially out, the attribute type of the feature object on the boundary where the cell is located is used to determine the active/inactive status of the cell. An example of this process is shown in the figure at the right.
If an arc on the boundary of the model domain has no attribute assigned to it, it is assumed to be a no-flow boundary. If a cell is partially covered by a no-flow boundary, the cell is activated if the majority of the cell area is inside the coverage. Conversely, the cell is inactivated if the majority of the cell area is outside the coverage. As a result, the outer edges of the cells along the no-flow boundary approximately coincide with the no-flow arc.
If an arc on the boundary of the model domain has a head dependent attribute assigned to it, a different test is used. Any cell that intersects the arc is designated as active, regardless of what percentage of the cell is inside the model domain. As a result, the centers of the cells along the boundary approximately coincide with the source/sink arc. This is appropriate in this case since the stresses are applied in MODFLOW at the cell centers.
GMS – Groundwater Modeling System | ||
---|---|---|
Modules: | 2D Grid • 2D Mesh • 2D Scatter Point • 3D Grid • 3D Mesh • 3D Scatter Point • Boreholes • GIS • Map • Solid • TINs • UGrids | |
Models: | FEFLOW • FEMWATER • HydroGeoSphere • MODAEM • MODFLOW • MODPATH • mod-PATH3DU • MT3DMS • MT3D-USGS • PEST • PHT3D • RT3D • SEAM3D • SEAWAT • SEEP2D • T-PROGS • ZONEBUDGET | |
Aquaveo |