Line 6: | Line 6: | ||
* ''Type'' – Each node can be assigned as one of the following types: "Generic", "Inlet – Circular", "Inlet – Rectangular", "Inlet – Weir", or "Inlet – From Database". | * ''Type'' – Each node can be assigned as one of the following types: "Generic", "Inlet – Circular", "Inlet – Rectangular", "Inlet – Weir", or "Inlet – From Database". | ||
* ''User specified Id'' – Allows specifying a name for the node. | * ''User specified Id'' – Allows specifying a name for the node. | ||
* ''Create connection to 2D domain (SX) | * ''Create connection to 2D domain (SX)'' – Connect 1D nodes to the 2D domain. | ||
** ''Force cell z to at or below node z (invert/ground level)(SXZ)'' | ** ''Force cell z to at or below node z (invert/ground level)(SXZ)'' | ||
** ''Lower 2D cell elevation (SXL) | ** ''Lower 2D cell elevation (SXL)'' – Specified to connect the 1D node to the 2D domain and lower the 2D cell by the given value. | ||
** ''Don't alter cell Z'' | ** ''Don't alter cell Z'' | ||
*** ''Method to choose additional cells'' | *** ''Method to choose additional cells'' | ||
** ''Method to determine number of connected 2D cells'' – Provides | ** ''Method to determine number of connected 2D cells'' – Provides two options: "Automatic Plus" or "Specified". | ||
*** ''Number of Additional'' | *** ''Number of Additional'' | ||
*** ''Number of Cells'' | *** ''Number of Cells'' | ||
Line 25: | Line 25: | ||
*''Additional Nodal'' – Adds the value specified as additional nodal area. | *''Additional Nodal'' – Adds the value specified as additional nodal area. | ||
*''Ground Level'' | *''Ground Level'' | ||
*''Invert (bottom)'' – The bottom elevation of the | *''Invert (bottom)'' – The bottom elevation of the node. | ||
*''Number of inlets'' | *''Number of inlets'' | ||
*''Manhole'' – Allows manually defining manholes. Clicking the '''Manhole Attributes''' button will open the [[SMS:TUFLOW Manholes|''Manhole Attributes'']] dialog. | *''Manhole'' – Allows manually defining manholes. Clicking the '''Manhole Attributes''' button will open the [[SMS:TUFLOW Manholes|''Manhole Attributes'']] dialog. | ||
Line 35: | Line 35: | ||
**''Exit'' | **''Exit'' | ||
===Rectangular Inlet Options=== | ===Rectangular Inlet Options=== | ||
Shape | *Shape | ||
*''Width'' | **''Width'' | ||
*''Height'' | **''Height'' | ||
Contraction Coefficients | *Contraction Coefficients | ||
*''Width'' | **''Width'' | ||
*''Height'' | **''Height'' | ||
Losses | *Losses | ||
*''Entry'' | **''Entry'' | ||
*''Exit'' | **''Exit'' | ||
[[File:Rectangular Inlet Definition.PNG|thumb|none|400 px|Example rectangular inlet]] | |||
===Weir Inlet Options=== | ===Weir Inlet Options=== | ||
Line 59: | Line 60: | ||
{{Navbox SMS}} | {{Navbox SMS}} | ||
[[Category:TUFLOW]] | [[Category:TUFLOW|Net]] | ||
[[Category:TUFLOW Dialogs]] | [[Category:TUFLOW Dialogs|Net]] |
Latest revision as of 16:56, 24 April 2018
SMS's Network Node Attributes dialog has several new additions to the Create Connection to 2D Domain (SX) section. These new options allow controlling elevations at the connections, how many cells are connected, and the method for selection of additional cells (Grade or Sag). Each option correlates fairly directly to a TUFLOW field and some are labeled as such to make look-up easy.
The TUFLOW Network Node Attributes dialog has the following options:
- Type – Each node can be assigned as one of the following types: "Generic", "Inlet – Circular", "Inlet – Rectangular", "Inlet – Weir", or "Inlet – From Database".
- User specified Id – Allows specifying a name for the node.
- Create connection to 2D domain (SX) – Connect 1D nodes to the 2D domain.
- Force cell z to at or below node z (invert/ground level)(SXZ)
- Lower 2D cell elevation (SXL) – Specified to connect the 1D node to the 2D domain and lower the 2D cell by the given value.
- Don't alter cell Z
- Method to choose additional cells
- Method to determine number of connected 2D cells – Provides two options: "Automatic Plus" or "Specified".
- Number of Additional
- Number of Cells
Generic Node Options
- Nodal area curve
- "Overwrite existing storage"
- "Additional to existing storage"
- Set Channel Invert – Sets the inverts of connected channels. Default is "-99999".
- Manhole – Allows manually defining manholes. Clicking the Manhole Attributes button will open the Manhole Attributes dialog.
Inlet Options
- Additional Nodal – Adds the value specified as additional nodal area.
- Ground Level
- Invert (bottom) – The bottom elevation of the node.
- Number of inlets
- Manhole – Allows manually defining manholes. Clicking the Manhole Attributes button will open the Manhole Attributes dialog.
Circular Inlet Options
- Shape Diameter
- Contraction Coefficients Width
- Losses
- Entry
- Exit
Rectangular Inlet Options
- Shape
- Width
- Height
- Contraction Coefficients
- Width
- Height
- Losses
- Entry
- Exit
Weir Inlet Options
- Shape Width – Width of the weir in meters.
- Weir coefficient Multiplier –
From Database Inlet Options
- Inlet database name – Contains a list of available inlets from a database.
- Inlet Database – Opens the Inlet Database dialog.
Related Topics
SMS – Surface-water Modeling System | ||
---|---|---|
Modules: | 1D Grid • Cartesian Grid • Curvilinear Grid • GIS • Map • Mesh • Particle • Quadtree • Raster • Scatter • UGrid | |
General Models: | 3D Structure • FVCOM • Generic • PTM | |
Coastal Models: | ADCIRC • BOUSS-2D • CGWAVE • CMS-Flow • CMS-Wave • GenCade • STWAVE • WAM | |
Riverine/Estuarine Models: | AdH • HEC-RAS • HYDRO AS-2D • RMA2 • RMA4 • SRH-2D • TUFLOW • TUFLOW FV | |
Aquaveo • SMS Tutorials • SMS Workflows |