Points in a FEMWATER coverage are used to define injection and extraction wells. The point attributes are edited via the ''Point Properties'' dialog. The ''Point Attributes'' dialog is accessed by [[GMS:Feature Object Tool Palette|selecting a point(s)]] and then selecting the '''Attribute Table''' command in the coverage right-click option menu. Each point's properties are displayed in the spreadsheet. The options in the dialog are as follows. | Points in a FEMWATER coverage are used to define injection and extraction wells. The point attributes are edited via the ''Point Properties'' dialog. The ''Point Attributes'' dialog is accessed by [[GMS:Feature Object Tool Palette|selecting a point(s)]] and then selecting the '''Attribute Table''' command in the coverage right-click option menu. Each point's properties are displayed in the spreadsheet. The options in the dialog are as follows. | ||
*''Type'' – The type of point can be changed to either a well or an observation point. These options are available depending on what was selected in the ''Coverage Setup Dialog''. The type for each point is defaulted to "NONE" in the ''Type'' column pull-down list. | |||
*''Refine'' – If the Refine mesh around point option is selected, the edge length of the elements surrounding the node are set to the size entered in the Element size edit field when the 2D projection mesh is generated. (see: [[GMS:Map to Modules#Map to 2D Mesh|Map → 2D Mesh]]) | |||
*''Wells'' – To define a point as a extraction or injection well change the ''Type'' to "well" in the spreadsheet. For each well, a flow rate and a concentration can be assigned. Each well is also assigned a the top and bottom elevation of the screened interval. | |||
*The screened interval is used to determine which of the nodes in the 3D mesh are used to represent the well in the numerical model. When the [[GMS:Map to Models#Map to FEMWATER|'''Map → FEMWATER''']] command is selected, all nodes intercepted by the well screen are found and each node is marked as a point source/sink (a well node). The flow assigned to the well in the conceptual model is distributed to the mesh nodes using the logic illustrated below. A length of influence on the well screen is found for each node and the flux assigned to the node is proportional to the length of influence divided by the total screen length. | |||
:[[Image:screenlogic.png|thumb|center|380 px|''The distribution of flux rate to nodes overlapped by well screen.'']] | :[[Image:screenlogic.png|thumb|center|380 px|''The distribution of flux rate to nodes overlapped by well screen.'']] |