GMS:BCT Process: Difference between revisions

From XMS Wiki
Jump to navigationJump to search
Line 75: Line 75:
Inputs corresponding to the DDF (Density Driven Flow) package.
Inputs corresponding to the DDF (Density Driven Flow) package.
*''Use DFF Package'' – Checking on this option will activate the DFF package in simulation.
*''Use DFF Package'' – Checking on this option will activate the DFF package in simulation.
*Density of fresh water (RHOFRESH)
*''Density of fresh water (RHOFRESH)''
*Density of standard solution (RHOSTD)
*''Density of standard solution (RHOSTD)''
*Concentration of standard solution (CSTD)
*''Concentration of standard solution (CSTD)''





Revision as of 20:06, 21 August 2018

Example of the BCT Process dialog

The Block Centered Transport (BCT) processs is needed if transport or density dependent flow is to be included in the model.

The BCT Process dialog is divided into two parts: one on the left which shows the main sections, and one on the right which shows the inputs for the current section.

Comments

Comment lines can be added and will appear at the top of the BCT file. Use the Add Row Insert Row Icon.svg button to create comments. Comments can be removed using the Delete Row Delete Row Icon.svg button.

Variables

Variables corresponding to item 1a in the BCT input file.

  • Transport simulation flag (ITRNSP)
  • Cell-by-cell mass flux unit (IBCTCB)
  • Number of mobile species (MCOMP)
  • Transport active domain (ICBNDFLG)
  • Advective term (ITVD)
  • Transport solution scheme (ICT)
  • Inactive node concentration (CINACT)
  • Concentration convergence tolerance (CICLOSE)
  • Dispersion formula (IDISP)
  • Cross dispersion (IXDISP)
  • Molecular diffusion coeff (DIFFNC)
  • Zero order decay (IZOD)
  • First order decay (IFOD)
  • Flux mass balance errors (IFMBC)
  • Flow imbalance unit (MBEGWUNF)
  • Mass imbalance unit (MBEGWUNT)
  • Flow imbalance unit for CLN (MBECLNUNF)
  • Mass imbalance unit for CLN (MBECLNUNT)

Species

The list of species. The number of species should equal the Number of mobile species (MCOMP) field in the Variables section. Each species should have a row in the section. On each row the Species ID is shown and the Species Name can be entered.

Use the Add Row Insert Row Icon.svg button to create species. Species can be removed using the Delete Row Delete Row Icon.svg button.

Aquifer Properties

Cell-by-cell inputs independent of species such as porosity. The table in this section contains four columns.

  • Property Name – This column lists all of the available parameter types. The following parameters are available:
  • Use Constant – Checking on this option indicates a constant value will be used for the parameter instead of an array.
  • Constant Value – A value that will be used for the parameter if an array is not being used.
  • Array Editor – Clicking the Edit button will open the array editor dialog where array values can be entered.

Species Properties

Cell-by-cell inputs that depend on the species, such as adsorption. The table in this section contains five columns.

  • Species ID
  • Property Name
  • Use Constant – Checking on this option indicates a constant value will be used for the parameter instead of an array.
  • Constant Value – A value that will be used for the parameter if an array is not being used.
  • Array Editor – Clicking the Edit button will open the array editor dialog where array values can be entered.

DDF Comments

Comment lines can be added and will appear at the top of the DDF file. Use the Add Row Insert Row Icon.svg button to create comments. Comments can be removed using the Delete Row Delete Row Icon.svg button.

DDF Package

Inputs corresponding to the DDF (Density Driven Flow) package.

  • Use DFF Package – Checking on this option will activate the DFF package in simulation.
  • Density of fresh water (RHOFRESH)
  • Density of standard solution (RHOSTD)
  • Concentration of standard solution (CSTD)