GMS:File Import Wizard Supported File Formats

From XMS Wiki
Revision as of 21:26, 16 December 2014 by Jcreer (talk | contribs)
Jump to navigationJump to search


The File Import Wizard can import various types of data as described in the tables below.

2D scatter points

This will create new scatter points in a new 2D scatter set. Optionally the imported points can be filtered using the filter options available by selecting the Filter Options button.

Field Type Required Comments
X
Number
yes
Y
Number
yes
Label
Text
no
Dataset
Number
no
Any number of steady-state or transient datasets can be imported. When importing transient datasets, a dataset name and a time step must be specified for each transient column. Names and time steps are entered into the header row, separated by a vertical slash using the following format: "Name|Timestep". For example, "Dataset1|January 1, 1900". All time steps of a transient dataset should be given the same name.

Examples

These examples can be copied and pasted into GMS.

Steady state

"id"	"x"	"y"	"xylene"	"toluene 0.0"	"toluene 2.0"
"OW-21"	32.4	74.3	300	999	999
"OW-22"	93.4	32.3	84	398	401
"OW-23"	83.3	48.2	89	47	52
"OW-24"	46.8	29.1	207	147	134

Transient

"id"	"x"	"y"	"xylene|01/01/2000 00:00"	"xylene|01/01/2000 12:00"	"xylene|01/02/2000 00:00"
"OW-21"	32.4	74.3	300	87	276
"OW-22"	93.4	32.3	84	310	187
"OW-23"	83.3	48.2	89	148	198
"OW-24"	46.8	29.1	207	147	134
"OW-25"	40.3	50.1	158	213	32
"OW-26"	60.7	52.0	27	41	300
"OW-27"	78.7	72.9	264	275	206

3D scatter points

This will create new scatter points in a new 3D scatter set.

Field Type Required Comments
X
Number
yes
Y
Number
yes
Z
Number
yes
Label
Text
no
Material ID
Number
no
Dataset
Number
no
Any number of steady-state or transient datasets can be imported. When importing transient datasets, a dataset name and a time step must be specified for each transient column. Names and time steps are entered into the header row, separated by a vertical slash using the following format: "Name|Timestep". For example, "Dataset1|January 1, 1900". All time steps of a transient dataset should be given the same name.

Examples

These examples can be copied and pasted into GMS.

Steady state

"id"	"x"	"y"	"z"	"xylene"	"toluene 0.0"	"toluene 2.0"
"OW-21"	32.4	74.3	10.1	300	87	999
"OW-22"	93.4	32.3	25.7	84	310	187
"OW-23"	83.3	48.2	5.3	89	148	198
"OW-24"	46.8	29.1	-42.2	207	147	134

Transient

"id"	"x"	"y"	"z"	"xylene|01/01/2000 00:00"	"xylene|01/01/2000 12:00"	"xylene|01/02/2000 00:00"
"OW-21"	32.4	74.3	10.1	300	387	276
"OW-22"	93.4	32.3	25.7	84	310	187
"OW-23"	83.3	48.2	5.3	89	148	198
"OW-24"	46.8	29.1	-42.2	207	147	134

Observation data

This creates new feature points in the existing, active coverage. The active coverage must exist and have a steady state observation attribute (like "Head") defined.

Field Type Required Comments
Point Name
Text
no
X
Number
yes
Y
Number
yes
Z
Number
no
Layer
Number
no
The 3D grid layer the point is associated with.
Measurement
Text
no
Measurement name. Multiple measurements allowed.
Interval
Number
no
Use Interval and Confidence, or Std. Dev. but not both.
Confidence
Number
no
Use Interval and Confidence, or Std. Dev. but not both.
Standard Deviation
Number
no
Use Interval and Confidence, or Std. Dev. but not both.

Example

"id"	"x"	"y"	"z"	"lay"	"hd"	"int"	"conf"
"OBS_Q5"	23.3	44.2	32.2	1	567.5	1.2	95
"OBS_Q6"	83.3	84.3	32.2	1	555.3	1.4	90
"OBS_Q7"	85.3	39.3	33.2	1	999	0	0

Transient observation data

This adds time series curves to existing points in an existing observation coverage. The targeted coverage must be the active coverage.

The existing points and the data being imported are matched by Name or ID. If both Name and ID are specified then ID will take precedence.

Both Date and Time can be specified although data can be imported with only Date or only Time specified (at least one of these fields must be specified). If only the Date is specified then the time is set to 12:00:00 AM. If only Time is specified then it is assumed that the user is not using date/time format and the time is treated as a relative time.

Field Type Required Comments
Name
Text
no
Either Name or ID must be specified
ID
Text
no
Either Name or ID must be specified
Date
Date
no
Either Date or Time or both must be specified
Time
Time
no
Either Date or Time or both must be specified

Example

"id"	"date"	"time"	"head"	
"OBS_Q5"	12/3/1999	18:00:00	238.5
"OBS_Q5"	1/30/2000	07:38:25	834.7
"OBS_Q6"	3/27/2000	18:00:00	878.3
"OBS_Q6"	12/3/1999	18:00:00	733.2

Well data

This creates new feature points in an existing coverage. The point types are set to "well" and the flow rate and other data are assigned to the points. A coverage with the "Wells" attribute must already exist and be the active coverage.

Field Type Required Comments
Name
Text
no
X
Number
yes
Y
Number
yes
Z
Number
no
Elevation of top of well.
Depth
Number
no
Depth to top of screen.
Screen Length
Number
no
Flow Rate
Number
no
Positive for injection, negative for extraction.

Example

"id"	"x"	"y"	"z"	"depth"	"len"	"Q"
"well_1"	123.5	843.2	62.0	51.4	6.0	120.5
"well_2"	134.2	789.4	62.8	60.7	5.4	100.3
"well_3"	147.2	678.1	61.4	110	10.0	300.5

MODFLOW Well Package data

This creates new well BCs in an existing MODFLOW simulation. Both steady state (one flow rate per well) or transient data (multiple flow rates at different times per well) can be imported. With transient data, multiple rows are used to list flow rates at different times (or date/times) and the Well Name field is used to associate the flow rates with the correct well. The times for changes in flow rate do not need to match the model stress period times. Flow rate curves are treated as stair step data and the rate for each stress period is found by temporal (time) interpolation. The user is asked if they want to use the average flow rate for each stress period, or use the flow rate at the beginning of each stress period.

Field Type Required Comments
Layer
Number
yes
Row
Number
yes
Column
Number
yes
Well Name
Text
yes
Any text used as the well identifier.
Flow Rate
Number
no
Positive for injection, negative for extraction.
Date
Date
no
If neither Date nor Time is specified, all stress periods will have the same Q.
Time
Time
no
Use this field for relative times (starting from 0.0), or if specifying an actual time of day (5:00) to go with the Date field. If neither Date nor Time is specified, all stress periods will have the same Q.

Example

"Layer"	"Row"	"Column"	"Rate"	"Well Name"	"Date"	"Time"
1	2	2	-502	City Well #1	Jan 1, 1940	5:00
1	2	2	-431	City Well #1	July 1, 1940	5:00
1	4	4	0	W5088341	July 1, 1940	5:00
1	4	4	-1000	W5088341	July 1, 1941	6:00

Pumping data

This adds time series curves to existing points in an existing coverage containing wells. The targeted coverage must be the active coverage. The existing points and the data being imported are matched by name.

Field Type Required Comments
Well Name
Text
yes
Must match an existing well, or else data is ignored.
Date
Date
No
Either Date or Time or both must be specified.
Time
Time
No
Either Date or Time or both must be specified.
Flow Rate
Number
yes
Positive for injection, negative for extraction.
Depth
Number
no
Depth to top of screen.
Screen Length
Number
no

Example

"id"	"date"	"time"	"Q"	
"well_1"	12/3/1999	18:00:00	625.0
"well_1"	1/30/2000	07:38:25	0
"well_2"	12/3/1999	18:00:00	0
"well_2"	3/3/2000	14:48:32	100.0

Borehole data

This creates new boreholes. Optionally, a borehole folder name can be specified to organize the imported boreholes.

Field Type Required Comments
Borehole Name
Text
yes
X
Number
yes
X location of the contact.
Y
Number
yes
Y location of the contact.
Z
Number
yes
Z location of the contact.
HGU ID
Number
yes
HGU Material below the contact
Material ID
Number
no
Material below the contact.
Horizon ID
Number
no
"id"	"x"	"y"	"z"	"material"	"horizon"
"borehole_1"	0.0	0.0	0.0	3	1
"borehole_1"	0.0	0.0	10.0	1	2
"borehole_1"	0.0	0.0	15.0	6	4
"borehole_2"	5.0	0.0	1.0	2	3
"borehole_2"	5.0	0.0	6.0	2	4

Borehole sample data

This creates new sample data on existing boreholes, or new sample data on new boreholes if no boreholes with matching names exist. All existing sample data is replaced with that being imported.

Field Type Required Comments
Name
Text
yes
New Borehole Name
X
Number
yes
X location of the borehole.
Y
Number
yes
Y location of the borehole.
Z
Number
yes
Z location of the borehole.
Dataset
Number
yes
"id"	"x"	"y"	"z"	"data"
"borehole_1"	0.0	0.0	0.0	495
"borehole_1"	0.0	0.0	10.0	484
"borehole_1"	0.0	0.0	15.0	454
"borehole_2"	5.0	0.0	1.0	259
"borehole_2"	5.0	0.0	6.0	248

Transient point data

This creates new time series curve data on existing feature points similar to the "Pumping data" option above. This option is more generic than the "Pumping data" option, however, because it will work with feature points of any type and any attribute (that can be transient) of that feature point.

The existing points and the data being imported are matched by Name or ID or X and Y. The order of precedence for these fields is ID, Name, then X and Y.

Both Date and Time can be specified although data can be imported with only Date or only Time specified (at least one of these fields must be specified). If only the Date is specified then the time is set to 12:00:00 AM. If only Time is specified then it is assumed that the user is not using date/time format and the time is treated as a relative time.

Data for more than one attribute can be imported at the same time. The attributes of the active coverage are listed as available fields that can be mapped.

Field Type Required Comments
Name
Text
No
Name or ID or X and Y must be specified.
ID
Number
No
Name or ID or X and Y must be specified.
Date
Date
No
Either Date or Time or both must be specified.
Time
Time
No
Either Date or Time or both must be specified.
X
Number
No
Name or ID or X and Y must be specified.
Y
Number
No
Name or ID or X and Y must be specified.
[Attribute1...]
Number
No
The value of the selected attribute at the given date/time.
[AttributeN]
Number
No
The value of the selected attribute at the given date/time.
"id"	"date"	"time"	"x"	"y"	"Flow rate"
"well_1"	12/3/1999	18:00:00	123.5	843.2	625
"well_1"	1/30/2000	07:38:25	123.5	843.2	0
"well_2"	3/27/2000	18:00:00	134.2	789.4	0
"well_2"	12/3/1999	18:00:00	134.2	789.4	100.0

Transient node data

Similar to Transient point data but for nodes. Since nodes don't have names they must be matched by ID or XY location.

Field Type Required Comments
ID
Number
No
Either ID or X and Y must be specified.
Date
Date
No
Either Date or Time or both must be specified.
Time
Time
No
Either Date or Time or both must be specified.
X
Number
No
Either ID or X and Y must be specified.
Y
Number
No
Either ID or X and Y must be specified.
[Attribute1...]
Number
No
The value of the selected attribute at the given date/time.
[AttributeN]
Number
No
The value of the selected attribute at the given date/time.

Transient arc data

Similar to Transient point data but for arcs. Since arcs don't have a single XY location they must be matched by ID or Name.

Field Type Required Comments
Name
Text
No
Either Name or ID must be specified.
ID
Number
No
Either Name or ID must be specified.
Date
Date
No
Either Date or Time or both must be specified.
Time
Time
No
Either Date or Time or both must be specified.
[Attribute1...]
Number
No
The value of the selected attribute at the given date/time.
[AttributeN]
Number
No
The value of the selected attribute at the given date/time.

Transient polygon data

Similar to Transient point data but for polygons. Since polygons don't have a single XY location they must be matched by ID or Name.

Field Type Required Comments
Name
Text
No
Name or ID must be specified.
ID
Number
No
Name or ID must be specified.
Date
Date
No
Either Date or Time or both must be specified.
Time
Time
No
Either Date or Time or both must be specified.
[Attribute1...]
Number
No
The value of the selected attribute at the given date/time.
[AttributeN]
Number
No
The value of the selected attribute at the given date/time.