The ''ADH Model Control'' dialog contains the graphical prompts for specifying model options.  The dialog is accessed through the ''ADH'' | '''Model Control...''' menu item.  
The ''ADH Model Control'' dialog contains the graphical prompts for specifying model options.  The dialog is accessed through the ''ADH'' | '''Model Control...''' menu item.  



Revision as of 19:30, 27 May 2015

File:ADH Model Control Parameters.jpg
Model Parameters tab of the ADH Model Control dialog

The ADH Model Control dialog contains the graphical prompts for specifying model options. The dialog is accessed through the ADH | Model Control... menu item.

Dialog Description

Model control contains the following pages:

ADH Model Control Output

This page window is accessed from the Model Control window by clicking on the Output tab.

ADH will write solution data at startup and at each time step specified in a XY1 series definition and referred to by the OC card. Flux data will be included with the solution data if output flow strings are specified (see assigning boundary conditions).

ADH Model Control Advanced (Cards)

Model options not available in the interface can be specified in the ADH model control under the advanced tab. Each row in the spreadsheet will be saved as a different line in the *.bc file. The cards can be inserted and deleted using the insert and delete rows.

  • The lines will be written out exactly as typed.
  • The lines will be written out in the order in which they appear in the dialog.
  • Any lines encountered in a *.bc file that is not recognized will appear in this list.
  • Lines beginning with a "!" character are treated as comment lines and will be skipped over during a read.
  • Comment lines are automatically generated and will not be preserved.
  • All of these advanced cards will be grouped together at the bottom of the file regardless of where they appeared during reading.

Dialog Description

The following controls specify how often solution data will be written by ADH and the number of flux boundaries present.

Output Times

List box contains the times to be contained in the output series. Multiple selection is enabled for deleting times.

Add by specifying a range / Add individual output time radio group specifies time information to be added. The Add by specifying a range control group includes Start at positive integer/real number field and units combo box, End at positive integer/real number field, and Increment positive integer/real number field and units combo box. The End at time units are the same as specified for the Start at time. The Add individual output time control includes a positive integer/real number field and units combo box. Each edit field allows for positive integer seconds or positive real number minutes, hours, etc., with six decimal places. All times are rounded to the nearest whole second (a decimal minute is rounded to the nearest decimal minute with a whole second equivalent) before being added.

Add button includes the time information from the above radio group in the times list box. Duplicate times will be automatically removed from the list.

Delete button removes the selected time(s) from the list box.

Delete All buttons clears the entire times list without regard to the current selection.

View output times in combo box specifies the time unit the list box will display the output times in.

Specify curve fit tolerance check box and positive integer edit field specifies the series tolerance when checked.

Flow

Number of nodestrings specified to output flow calculated across themselves displays the total number of ADH flux boundaries included in the simulation.