SMS:FESWMS Menu: Difference between revisions
From XMS Wiki
Jump to navigationJump to search
No edit summary |
|||
Line 1: | Line 1: | ||
The following menu commands are available in the [[SMS:FESWMS|FESWMS]] Menu: | The following menu commands are available in the [[SMS:FESWMS|FESWMS]] Menu: | ||
* '''Assign BC''' (Boundary Condition) – | * '''Assign BC''' (Boundary Condition) – Opens either the [[SMS:FESWMS BC Nodestrings|''FESWMS Nodestring Boundary Conditions'']] dialog or the ''FESWMS Nodal Boundary Conditions'' dialog. A node or nodestring must be selected for this command to be available. | ||
* '''Local Parameters''' – | * '''Local Parameters''' – Brings up the ''FESWMS Local Parameters'' dialog. Requires that a node be selected. | ||
* '''Initial Conditions''' – | * '''Initial Conditions''' – Brings up the ''Initial Conditions Data'' dialog. | ||
* [[SMS:FESWMS_Hydraulic_Structures#Weir|'''Weir''']] – | * [[SMS:FESWMS_Hydraulic_Structures#Weir|'''Weir''']] – Opens the ''FESWMS Weir'' dialog. Requires a selected nodestring be active. | ||
* [[SMS:FESWMS_Hydraulic_Structures#Culvert|'''Culvert''']] – | * [[SMS:FESWMS_Hydraulic_Structures#Culvert|'''Culvert''']] – Brings up the ''FESWMS Culvert'' dialog. Requires that the inlet and outlet nodes are currently selected. | ||
* [[SMS:FESWMS_Hydraulic_Structures#Drop-Inlet_Spillways|'''Drop Inlet''']] – | * [[SMS:FESWMS_Hydraulic_Structures#Drop-Inlet_Spillways|'''Drop Inlet''']] – Brings up the ''Drop Inlet Definition'' dialog. Requires that a node is currently selected. | ||
* [[SMS:FESWMS_Hydraulic_Structures#Channel Link|'''Channel Link''']] – | * [[SMS:FESWMS_Hydraulic_Structures#Channel Link|'''Channel Link''']] – Brings ups the ''FESWMS Channel Link'' dialog. | ||
* [[SMS:FESWMS_Hydraulic_Structures#Gate|'''Gate''']] – | * [[SMS:FESWMS_Hydraulic_Structures#Gate|'''Gate''']] – Opens the ''FESWMS Gate'' dialog. | ||
* [[SMS:FESWMS_Hydraulic_Structures#Piers|'''Pier''']] – | * [[SMS:FESWMS_Hydraulic_Structures#Piers|'''Pier''']] – Brings ups the ''FESWMS Pier Definition'' dialog. | ||
* '''FLUX String''' – | * '''FLUX String''' – Option to set currently selected nodestring to Total Flow string. | ||
* [[SMS:FESWMS Material Properties|'''Material Properties''']] – | * [[SMS:FESWMS Material Properties|'''Material Properties''']] – Opens the ''FESWMS Material Properties'' dialog. This dialog is different than the general ''Material Properties'' dialog in SMS. | ||
* [[SMS:Model Checker|'''Model Check''']] – | * [[SMS:Model Checker|'''Model Check''']] – Runs the model check. If there are errors, then the ''Model Check'' dialog will appear. | ||
* [[SMS:FESWMS_Model_Control_Dialog|'''Model Control''']] – | * [[SMS:FESWMS_Model_Control_Dialog|'''Model Control''']] – Brings up the ''FESWMS Model Control'' dialog. | ||
* '''Run FST2DH''' – | * '''Run FST2DH''' – Starts the FST2DH model wrapper. | ||
== Local Parameters Dialog== | == Local Parameters Dialog== |
Revision as of 17:13, 17 February 2016
The following menu commands are available in the FESWMS Menu:
- Assign BC (Boundary Condition) – Opens either the FESWMS Nodestring Boundary Conditions dialog or the FESWMS Nodal Boundary Conditions dialog. A node or nodestring must be selected for this command to be available.
- Local Parameters – Brings up the FESWMS Local Parameters dialog. Requires that a node be selected.
- Initial Conditions – Brings up the Initial Conditions Data dialog.
- Weir – Opens the FESWMS Weir dialog. Requires a selected nodestring be active.
- Culvert – Brings up the FESWMS Culvert dialog. Requires that the inlet and outlet nodes are currently selected.
- Drop Inlet – Brings up the Drop Inlet Definition dialog. Requires that a node is currently selected.
- Channel Link – Brings ups the FESWMS Channel Link dialog.
- Gate – Opens the FESWMS Gate dialog.
- Pier – Brings ups the FESWMS Pier Definition dialog.
- FLUX String – Option to set currently selected nodestring to Total Flow string.
- Material Properties – Opens the FESWMS Material Properties dialog. This dialog is different than the general Material Properties dialog in SMS.
- Model Check – Runs the model check. If there are errors, then the Model Check dialog will appear.
- Model Control – Brings up the FESWMS Model Control dialog.
- Run FST2DH – Starts the FST2DH model wrapper.
Local Parameters Dialog
Initial Conditions Dialog
Run FST2DH
Related Topics
SMS Menu Bars | |
---|---|
Standard Menus: | File • Edit • Display • Window • Help |
Module Menus: | 2D Mesh • Cartesian Grid • Curvilinear Grid • GIS • Map • Particle • Quadtree • Raster • Scatter |
Model Menus: | ADCIRC • BOUSS-2D • CGWAVE • CMS-Flow • CMS-Wave • FESWMS • Generic Model • GenCade • PTM • RMA2 • RMA4 • SRH-2D • STWAVE • TUFLOW |
SMS – Surface-water Modeling System | ||
---|---|---|
Modules: | 1D Grid • Cartesian Grid • Curvilinear Grid • GIS • Map • Mesh • Particle • Quadtree • Raster • Scatter • UGrid | |
General Models: | 3D Structure • FVCOM • Generic • PTM | |
Coastal Models: | ADCIRC • BOUSS-2D • CGWAVE • CMS-Flow • CMS-Wave • GenCade • STWAVE • WAM | |
Riverine/Estuarine Models: | AdH • HEC-RAS • HYDRO AS-2D • RMA2 • RMA4 • SRH-2D • TUFLOW • TUFLOW FV | |
Aquaveo • SMS Tutorials • SMS Workflows |