WMS:CE-QUAL-W2 Layer Editor: Difference between revisions

From XMS Wiki
Jump to navigationJump to search
No edit summary
No edit summary
 
(8 intermediate revisions by the same user not shown)
Line 1: Line 1:
The layer editor is used for generating a storage capacity curve for a CE-QUAL-W2 application.  The curve is computed from selected segment(s) of a representative waterbody and is generated by selecting the '''Compute storage-capacity curve''' button.  Generation of the curve may take some time, especially where several segments have been selected.   
The layer editor is used for generating a storage capacity curve for a CE-QUAL-W2 application.  The curve is computed from selected segment(s) of a representative waterbody and is generated by selecting the '''Compute Rating Curve''' button.  Generation of the curve may take some time, especially where several segments have been selected.   


The '''Plot storage-capacity curve''' button produces a separate image of the storage capacity curve.  This image has several options which can be displayed by right clicking the mouse over the image.
The '''Plot Rating Curve''' button produces a separate image of the storage capacity curve.  This image has several options which can be displayed by right clicking the mouse over the image.


The '''Compute Top Elevation''' button will give the top elevation of the TIN in the ''Top elevation'' text box.  It should be noted that this is not necessarily the top elevation of the waterbody.  If the top elevation of the waterbody is desired then it should be manually input into the ''Top elevation'' text box.
The '''Compute Top Elevation''' button will give the top elevation of the TIN in the ''Top elevation'' text box.  It should be noted that this is not necessarily the top elevation of the waterbody.  If the top elevation of the waterbody is desired then it should be manually input into the ''Top elevation'' text box.


The ''Layer Generation'' pulldown box gives the user two options for the number of layers in the bathymetry file.  If the user desires to prescribe the number of layers then the ''Number of layers'' option should appear in the box and the desired number of layers entered in the text box titled value.  If the user desires a certain layer height then the ''Layer heights'' option should be selected with the desired value for layer heights entered in the Value text box.  Selecting the '''Compute''' button will compute the number of layers and/or layer heights for the waterbody.  The layers will then appear in the large text box for viewing.  These can be edited according the user's needs by using the '''Add Layer''' and '''Delete Layer''' button.  Individual layer heights are shown in the ''Layer height'' text box.
The ''Layer Generation'' pulldown box gives two options for the number of layers in the bathymetry file.  If wanting to prescribe the number of layersthe ''Number of layers'' option should appear in the box and the desired number of layers entered in the text box titled value.  If wanting a certain layer height, the ''Layer heights'' option should be selected with the desired value for layer heights entered in the ''Value'' text box.  Selecting the '''Compute''' button will compute the number of layers and/or layer heights for the waterbody.  The layers will then appear in the large text box for viewing.  These can be edited accordingly by using the '''Add Layer''' and '''Delete Layer''' button.  Individual layer heights are shown in the ''Layer height'' text box.


Selecting the '''Calculate Widths''' button will calculate the widths of all selected segments.
Selecting the '''Calculate Widths''' button will calculate the widths of all selected segments.


 
[[Image:CE-QUAL-W2layereditor.jpg|thumb|none|left|500 px|''CE-QUAL-W2 Layer Editor'' dialog]]
[[Image:W2Image210.jpg]]




Line 18: Line 17:


{{WMSMain}}
{{WMSMain}}
[[Category:CE-QUAL-W2|L]]
[[Category:CE-QUAL-W2 Dialogs|L]]

Latest revision as of 15:05, 6 October 2017

The layer editor is used for generating a storage capacity curve for a CE-QUAL-W2 application. The curve is computed from selected segment(s) of a representative waterbody and is generated by selecting the Compute Rating Curve button. Generation of the curve may take some time, especially where several segments have been selected.

The Plot Rating Curve button produces a separate image of the storage capacity curve. This image has several options which can be displayed by right clicking the mouse over the image.

The Compute Top Elevation button will give the top elevation of the TIN in the Top elevation text box. It should be noted that this is not necessarily the top elevation of the waterbody. If the top elevation of the waterbody is desired then it should be manually input into the Top elevation text box.

The Layer Generation pulldown box gives two options for the number of layers in the bathymetry file. If wanting to prescribe the number of layers, the Number of layers option should appear in the box and the desired number of layers entered in the text box titled value. If wanting a certain layer height, the Layer heights option should be selected with the desired value for layer heights entered in the Value text box. Selecting the Compute button will compute the number of layers and/or layer heights for the waterbody. The layers will then appear in the large text box for viewing. These can be edited accordingly by using the Add Layer and Delete Layer button. Individual layer heights are shown in the Layer height text box.

Selecting the Calculate Widths button will calculate the widths of all selected segments.

CE-QUAL-W2 Layer Editor dialog