Revision as of 17:15, 3 March 2014
There are three different methods for defining storage capacity: volume vs. elevation, area vs. elevation, and known geometry.
In all three cases a relationship between elevation and volume will be computed. For the volume vs. elevation option this is explicitly defined. If area vs. elevation is specified, then a corresponding volume for each elevation is computed using the conic method. The conic method is illustrated below.
The volume between incremental areas and is computed using the following equation:
where:
- – The volume between areas and .
- – surface area .
- – vertical distance between surface areas and .
- – elevation of surface area .
The same equation is used to compute the volume between each adjacent set of surface areas, with the bottom area assumed to be 0. A TIN can be used to automatically create and store for use in the detention basin calculator the elevation-volume relationship.
If the basin geometry option is chosen then an elevation vs. volume relationship is computed directly from the geometry defined for the basin.