WMS:Repeated Use of an Equation
If your local hydrology manual requires the use of an equation not currently supported by WMS and you must repeatedly use this equation for projects, you can set up the equation in a text file in the same directory as WMS and it will be read in and set up as the User Defined equation automatically. To do this you must create a file named "wmstc.equ" and define one or more equation groups (a group may be used because sometimes your equation to compute a travel time may be a function of another equation). The following is an example wmstc.equ file.
EQGROUP Myeq1 EQ 1.49 / n * R * Sc DEF Manning's equation UNITS laghour VAR n DEF Manning's roughness coefficient VAL .002 UNITS none WHICH -1 VAR R DEF Hydraulic Radius VAL 0.0 UNITS ft WHICH 2 EQ XA / Pw DEF Hydraulic Radius UNITS ft VAR XA DEF Cross section area VAL 0.0 UNITS sqft WHICH -1 VAR Pw DEF Wetted Perimeter VAL 0.0 UNITS ft WHICH -1 EQGROUP Myequ2 EQ Lc / V DEF Time of travel UNITS lagmin VAR V DEF Velocity VAL 2.5 UNITS none WHICH -1
The following describes the keywords used in the file as well as the possible values that can be entered following each keyword.
Each equation group begins with the EQGROUP card. The rest of the line is interpreted as a character string and used as the name of the equation group in the drop-down combo box allowing you to select an equation.
Each equation is defined using the following three cards with their associated inputs:
EQ – The equation
DEF – A character string definition for the equation
UNITS – Units of the computed result. Possible values for units include: laghour, lagmin, tchour, tcmin, clarkr, tp. The first four identify whether the equation is intended for use in computing lag time or time of concentration (a conversion to the other is done using this equation) and whether the result is in minutes or hours. The last three are used if the equation is used to compute the Clark storage coefficient or one of the peaking parameters used in HEC-1.
If one of the WMS recognized variables are used (A, Lca, etc.) then you do not need to include a VAR record as it will automatically map the WMS variable for use in the equation. For variables not recognized as something WMS computes you should include a VAR line that uses the following keywords:
VAR – Name of the variable
DEF – Variable definition or description
VAL – The initial default value (should be 0.0 if this will be entered separately for each basin)
UNITS - The units of the variable. The following list of keywords are recognized for units. If you use a variable with units not in this list you should enter "none" and then make sure that the equation is dimensionally consistent with the units defined for the equation on the EQ line.
laghour | |
tcmin | |
tchour | |
lagmin | |
mi | mile |
m | meter |
ft | feet |
km | kilometer |
hr | hour |
sec | second |
none | none |
acre | acre |
sqkm | square kilometer |
sqmi | square mile |
sqft | square feet |
sqm | square meter |
in | inch |
mm | millimeter |
hect | hectare |
WHICH - If a variable represents another equation that is part of the equation group then you should follow the WHICH keyword with the equation number. If it does not represent another equation then you should follow it with a -1. See the example above where the hydraulic radius variable R represents the second equation in the group (XA/Pw).
You may define as many equations as you want in the file and each time WMS is started the equations will be read and become members in the list of equations you can select from when defining travel times from basin data.