GMS:MODFLOW Display Options: Difference between revisions

From XMS Wiki
Jump to navigationJump to search
No edit summary
No edit summary
 
(One intermediate revision by one other user not shown)
Line 1: Line 1:
{{MODFLOW Links}}
{{MODFLOW Links}}
The properties of all MODFLOW data that GMS displays on the screen can be controlled through the MODFLOW tab of the ''Display Options'' dialog. This dialog is opened by right-clicking on the [[File:MODFLOW Folder.svg|16 px]] MODFLOW entry in the [[GMS:Project Explorer|Project Explorer]] and selecting the '''Display Options''' command. It can also be accessed from the from the ''Display'' menu, the ''MODFLOW'' menu, or the '''Display Options''' [[File:Display Options Macro.svg|16 px]] macro. The following table describes the display options available for MODFLOW models.
The properties of all MODFLOW data that GMS displays on the screen can be controlled through the MODFLOW tab of the ''Display Options'' dialog. This dialog is opened by right-clicking on the [[File:MODFLOW Folder.svg|16 px]] MODFLOW entry in the [[GMS:Project Explorer|Project Explorer]] and selecting the '''Display Options''' command. It can also be accessed from the ''Display'' menu, the ''MODFLOW'' menu, or the '''Display Options''' [[File:Display Options Macro.svg|16 px]] macro. The following table describes the display options available for MODFLOW models.


{| class="wikitable"
{| class="wikitable"
Line 26: Line 26:
|-
|-
| Check None ||Turns off all display options.
| Check None ||Turns off all display options.
<!--|-
|-
|Display Values || Option for either the key values or the final array values to be used for display.-->
|Display Values || Option for either the [[GMS:Parameters#Key_Values|key values]] or the final array values to be used for display. For MODFLOW datasets that have both key values and array values defined, this option sets which values display in the ''Edit Dataset Values'' dialog. It also sets which values display in the Graphics Window when MODFLOW datasets with both kinds of values are the active dataset. This setting can also be adjusted using the right-click menu in the Project Explorer for MODFLOW datasets that have both types of values. This option has no effect for datasets that don't have both key values and array values
*Display final array values &ndash; Displays array values associated with each cell. They represent the actual value for a specific input parameter. These may be values specified by the user or might be values calculated using MODFLOW.
*Display key values &ndash; Displays the key values used for parameterization of the selected dataset. Only available if the [[GMS:Parameters#Key_Values|key values approach to parameterization]] is used. These values are used to define zones, but are not the actual value of a specific parameter. They are usually negative numbers that are not included in the actual dataset.
|-
|-
| Display symbol legend || If the ''Symbol legend'' option is selected, a legend showing each of the symbols associated with sources/sinks, dry cells, and flooded cells is displayed in the lower right corner of the GMS window.
| Display symbol legend || If the ''Symbol legend'' option is selected, a legend showing each of the symbols associated with sources/sinks, dry cells, and flooded cells is displayed in the lower right corner of the GMS window.

Latest revision as of 16:35, 2 April 2024

MODFLOW
Pre-processing
MODFLOW Commands
Building a MODFLOW Model
Map to MODFLOW
Calibration
Packages Supported in GMS
Saving a MODFLOW Simulation
Importing MODFLOW Files
Unsupported MODFLOW Features
Run MODFLOW
Post-processing
MODFLOW Display Options
MODFLOW Post-Processing Viewing Options
Reading a MODFLOW Simulation
Tutorials
Packages
Flow: BCF6, HUF, LPF, UPW
Solvers:

DE4, GMG, NWT, PCG,

PCGN, LMG, SIP, SOR,

SMS
Other:

BAS6, BFH, CHD1, CLN,

DRN1, DRT1, EVT1, ETS1,

GAGE, GHB1, GNC, HFB1,

HUF, LAK3, MNW1, MNW2,

OUT1, RCH1, RIV1, SFR2,

STR1, SUB1, SWI2, WEL1,

UZF1

The properties of all MODFLOW data that GMS displays on the screen can be controlled through the MODFLOW tab of the Display Options dialog. This dialog is opened by right-clicking on the MODFLOW Folder.svg MODFLOW entry in the Project Explorer and selecting the Display Options command. It can also be accessed from the Display menu, the MODFLOW menu, or the Display Options Display Options Macro.svg macro. The following table describes the display options available for MODFLOW models.

Display Option Description
Wells, Drains, Rivers, Streams, General head, Constant head, Transient head, CLN nodes These items represent source/sink objects. If the checkbox to the left of each source/sink name is selected, a symbol is displayed at the center of each cell with that type of source/sink. The symbol for each source/sink is displayed to the left of the checkbox. The symbol can be changed by selecting the symbol button. This brings up the symbol editor dialog. The symbol editor contains a list of available symbols. The dialog can also be used to edit the size and color of the symbol.
Dry cells Displays a symbol at the location of all dry cells in the grid. A MODFLOW solution must be imported to GMS prior to displaying dry cells. When a cell goes dry during a MODFLOW simulation, the HDRY value defined in the BCF Package is assigned as the head value for the cell. If an HDRY value is encountered in the active scalar dataset when the display is refreshed, the cell is assumed to be dry.
Flooded cells The computed water table elevation often exceeds the elevation of the ground surface. The Flooded cells option is used to draw a symbol at the center of all cells where the computed water table elevation is greater than the top elevation of the top layer in the grid.
Horiz. flow barrier Displays a line at the location of each horizontal barrier. The attributes (thickness, color, etc.) can be edited by clicking on the small window to the left of the Horiz. flow barrier checkbox.
Display hydrogeologic units The Display hydrogeologic units option is used to display HUF data. This option only works if the current display mode is Ortho Mode. This mode can be turned on in the Display menu.
Lake cells Draws a symbol in the center of each cell representing a lake. The symbol, the symbol size, and symbol color can be adjusted by clicking on the button to the left of the Lake cells checkbox.
Lake ID's Displays the lake ID in the center of each cell representing a lake. The font, font size, and font color can be adjusted by clicking on the button to the left of the lake ID's checkbox.
PCB Displays a symbol in the center of each cell that has a prescribed or constant concentration boundary. The symbol, the symbol size, and symbol color can be adjusted by clicking on the button to the left of the Lake cells checkbox.
Water table When a grid cross section is displayed in orthogonal mode, this tool superimposes the water table defined by a MODFLOW solution on the layer geometry. The water table is defined as the head value in the uppermost active cell. If the water table display is on, all contours (head, concentration, etc.) are clipped so that they lie at or below the water table. This option is only available if the True Layer display option is active under the 3D Grid display options tab.
Check All Turns on all display options.
Check None Turns off all display options.
Display Values Option for either the key values or the final array values to be used for display. For MODFLOW datasets that have both key values and array values defined, this option sets which values display in the Edit Dataset Values dialog. It also sets which values display in the Graphics Window when MODFLOW datasets with both kinds of values are the active dataset. This setting can also be adjusted using the right-click menu in the Project Explorer for MODFLOW datasets that have both types of values. This option has no effect for datasets that don't have both key values and array values
  • Display final array values – Displays array values associated with each cell. They represent the actual value for a specific input parameter. These may be values specified by the user or might be values calculated using MODFLOW.
  • Display key values – Displays the key values used for parameterization of the selected dataset. Only available if the key values approach to parameterization is used. These values are used to define zones, but are not the actual value of a specific parameter. They are usually negative numbers that are not included in the actual dataset.
Display symbol legend If the Symbol legend option is selected, a legend showing each of the symbols associated with sources/sinks, dry cells, and flooded cells is displayed in the lower right corner of the GMS window.
The Display Options dialog showing the MODFLOW tab of the 3D Grid Data item.