Line 27: | Line 27: | ||
* ''Relative convergence increase power (MCNVG)'' – Requires enhanced convergence mode. Increases the relative PCG convergence criteria by a power equal to MCNVG. | * ''Relative convergence increase power (MCNVG)'' – Requires enhanced convergence mode. Increases the relative PCG convergence criteria by a power equal to MCNVG. | ||
* ''Relative convergence enhancement (RATE_C)'' – Requires enhanced convergence mode. Results in variable enhancement of ε. | * ''Relative convergence enhancement (RATE_C)'' – Requires enhanced convergence mode. Results in variable enhancement of ε. | ||
* Progress reporting (IPUNIT) | * ''Progress reporting (IPUNIT)'' – Enables progress reporting for the Picard iteration. | ||
** (-1) None | ** (-1) None – Suppresses printing of all progress concerning the Picard iteration. | ||
** (0) Listing file | ** (0) Listing file – Prints a record of progress made by the Picard iteration for each time step in the MODFLOW Listing file. | ||
** (1) CSV file | ** (1) CSV file – Extensive diagnostics for each Picard iteration is written in comma-separated format to a file whose unit number corresponds to IPUNIT. | ||
For more information on this solver see the USGS documentation at http://water.usgs.gov/nrp/gwsoftware/modflow2000/MFDOC/pcgn.htm | For more information on this solver see the USGS documentation at http://water.usgs.gov/nrp/gwsoftware/modflow2000/MFDOC/pcgn.htm |