WMS:GSSHA: Difference between revisions

From XMS Wiki
Jump to navigationJump to search
No edit summary
 
(69 intermediate revisions by 6 users not shown)
Line 1: Line 1:
GSSHA is a two-dimensional finite difference rainfall/runoff model. A finite difference grid is used to establish the computational domain and parameters for surface runoff. The GSSHA model is fully coupled with hydraulic stream flow/routing models. Parameters for stream channels are defined using arcs and then mapped to the appropriate underlying grid cells.
{{TOC right}}
Gridded Surface Subsurface Hydrologic Analysis (GSSHA) is a two-dimensional finite difference rainfall/runoff model. A finite difference grid is used to establish the computational domain and parameters for surface runoff. The GSSHA model is fully coupled with hydraulic stream flow/routing models. Parameters for stream channels are defined using arcs and then mapped to the appropriate underlying grid cells.


A detailed online reference manual for GSSHA is found here:
Features of GSSHA include 1D stream flow and infiltration, 2D overland flow and groundwater, and full coupling between the groundwater, shallow soils, streams, and overland flow.<ref name="GSSHA overview">{{cite web|url=http://www.gsshawiki.com/Overview:Overview|title=Overview:Overview|publisher=GSSHA Wiki|accessdate=April 26, 2019}}</ref> "Sediment and constituent fate and transport are simulated in the shallow soils, overland flow plane, and in streams and channels. GSSHA can be used as an episodic or continuous model where soil surface moisture, groundwater levels, stream interactions, and constituent fate are continuously simulated. The fully coupled groundwater to surface-water interaction allows GSSHA to model basins in both arid and humid environments."<ref name="GSSHA overview"/>


[http://www.gsshawiki.com http://www.gsshawiki.com]
The GSSHA model can be added to a paid edition of WMS.<ref name="WMS Pricing">{{cite web|url=http://www.aquaveo.com/software/wms-pricing|title=WMS Editions & Pricing|publisher=Aquaveo|accessdate=April 26, 2019}}</ref>


==Model Check==
==GSSHA Menus==
[[Image:Dialog_GSSHA_Model_Check.png|thumb|350 px]]
There are two ''GSSHA'' menus in WMS:
The GSSHA '''Model Check''' command runs through the input data for a GSSHA simulation and looks for obvious inconsistencies and problems with the model. The model checker will not identify values that are outside of plausible ranges, etc., only logical problems. For example, an index map has one or more cells whose ID is 0 (which is not allowed in GSSHA), or a specified process that has an ID with parameters whose values are 0.00 (which indicates an incomplete entry). An example of a problem that the model checker would not find is if a stream arc has a pit that pools water.
*When in the '''Map Module''' [[File:Map Module Icon.svg|16px]], the ''GSSHA'' menu is available when a GSSHA coverage is selected. See [[WMS:GSSHA Menu#GSSHA Coverage Menu|here]] for more details.
*When in the '''2-D Grid Module''' [[File:2D Grid Icon.svg|16px]], the main ''GSSHA'' menu is available. See [[WMS:GSSHA Menu#GSSHA Grid Menu|here]] for more details.


==Run Simulation==
==Cell Properties==
The '''Run GSSHA''' command launches GSSHA in the WMS Model Wrapper. Select an existing GSSHA project file or specify the name and location of the GSSHA project file to be saved before running the simulation. The GSSHA Run Options include:
The 2D grid cell properties include an ''I,J'' location and a scalar or index map value. The scalar or index map value is associated with the currently selected dataset in the Project Explorer and can be edited in the Properties Window. The ''I,J'' location can be viewed but not edited in the Properties Window. The 2D grid contours are a way of visualizing the spatial variation of the scalar or index map values for the selected dataset.
* Suppress screen printing
* Save files before running
* Pause GSSHA window after running
The ''Suppress screen printing'' option suppresses the output of runtime data from GSSHA at each time step, but significantly reduces the overall run time required for a GSSHA simulation.  This option also requires that the GSSHA input files be saved before running the simulation.


[[Image:Dialog_GSSHA_Run_Options.png|thumb|none|left|300 px]]
==GSSHA Model Check==
{{anchor|Model Check}}[[File:Dialog GSSHA Model Check.png|thumb|right|380px|''GSSHA Model Check'' dialog]]
The ''GSSHA Model Check'' dialog lists potential problems with the GSSHA model. It is accessed by selecting ''GSSHA'' | '''Model Check...''' while in the '''2-D Grid Module''' [[File:2D Grid Icon.svg|14px]]. The model check runs through the input data for a GSSHA simulation and looks for obvious inconsistencies and problems with the model. The model check will find logical problems, but will not identify values that are outside of plausible ranges.


WMS will automatically read the GSSHA solution produced by the simulation when the '''Close''' button is clicked in the WMS Model Wrapper if the ''Read Solution on Exit'' option is toggled on.
An example of a problem that the model checker would not find is if a stream arc has a pit that pools water. Examples of potential problems that will be identified by the model check:
*An index map has one or more cells whose ID is "0" (which is not allowed in GSSHA).
*A specified process that has an ID with parameters whose values are "0.00" (which indicates an incomplete entry).  


Note: GSSHA currently supports file names (including path and file name) with lengths less than or equal to 128 characters. If GSSHA tutorial files are placed in a directory with a path that causes the combined path and file name to exceed 128 characters, then GSSHA will not run.
Clicking on a specific warning or error will open a dialog that will allow the potential problem to be fixed, if needed.


At the bottom of the dialog are three buttons:
*'''Help''' &ndash; Opens this article in a web browser.
*'''Done''' &ndash; Closes the ''GSSHA Model Check'' dialog.
*'''Print''' &ndash; Opens a ''Choose name of output file'' dialog. Enter the desired ''File name'' and click '''Save''' to export the model check information to a text file.


==GSSHA Run Options==
{{anchor|Run Options}}
[[File:Dialog GSSHA Run Options.png|thumb|right|280 px|''GSSHA Run Options'' dialog]]
The ''GSSHA Run Options'' dialog lists options for running the GSSHA model. It is accessed by selecting ''GSSHA'' | '''Run GSSHA...''' while in the '''2-D Grid Module''' [[File:2D Grid Icon.svg|14px]].


==Related Topics==
The following sections and options are found in this dialog:
* [[WMS:GSSHA Calibration|GSSHA Calibration]]
*''Location'' section &ndash; Lists the GSSHA project file that will be run. Click [[File:Open Macro.svg|16px]] to open a ''Save GSSHA Project File'' dialog. Select the desired project, or enter a new ''File name'' and click '''Save''' to close the ''Save GSSHA Project File'' dialog.
* [[WMS:GSSHA Cell Properties|GSSHA Cell Properties]]
*''Options'' section &ndash; The following options can be turned on or off:
* [[WMS:GSSHA Channel Routing|GSSHA Channel Routing]]
**''Suppress screen printing'' &ndash; Suppresses the output of runtime data from GSSHA at each time step, significantly reducing the overall run time required for a GSSHA simulation. This option requires that the ''Save file before running'' be turned on.
* [[WMS:GSSHA Contaminants|GSSHA Contaminants]]
**''Save file before running'' &ndash; Instructs GSSHA to save the project file prior to running GSSHA.
* [[WMS:GSSHA Digital Dams|GSSHA Digital Dams]]
**''Pause GSSHA window after running''
* [[WMS:GSSHA Embankment Arcs|GSSHA Embankment Arcs]]
* [[WMS:GSSHA Groundwater|GSSHA Groundwater]]
* [[WMS:GSSHA Maps|GSSHA Maps]]
* [[WMS:GSSHA Job Control|GSSHA Job Control]]
* [[WMS:GSSHA Join SSURGO Data|GSSHA Join SSURGO Data]]
* [[WMS:GSSHA Mapping Tables|GSSHA Mapping Tables]]
* [[WMS:GSSHA Maps|GSSHA Maps]]
* [[WMS:GSSHA Model Check|GSSHA Model Check]]
* [[WMS:GSSHA Multiple Scenarios|GSSHA Multiple Scenarios]]
* [[WMS:GSSHA Nutrients|GSSHA Nutrients]]
* [[WMS:GSSHA Open Project File|GSSHA Open Project File]]
* [[WMS:GSSHA Overland Soil Erosion|GSSHA Overland Soil Erosion]]
* [[WMS:GSSHA Output Control|GSSHA Output Control]]
* [[WMS:GSSHA Precipitation|GSSHA Precipitation]]
* [[WMS:GSSHA Read Solution|GSSHA Read Solution]]
* [[WMS:GSSHA Run Simulation|GSSHA Run Simulation]]
* [[WMS:GSSHA Save Project File|GSSHA Save Project File]]
* [[WMS:GSSHA Solution Analysis|GSSHA Solution Analysis]]


At the bottom of the dialog are the following buttons:
*'''OK''' &ndash; Saves the changes and opens the [[WMS:Model Wrapper|Model Wrapper]].
*'''Cancel''' &ndash; Cancels the GSSHA model run and closes the ''GSSHA Run Options'' dialog.


==Read GSSHA Solution==
{{anchor|Read Solution}}[[File:WMS Read GSSHA Solution dialog.png|thumb|right|280 px|''Read GSSHA Solution'' dialog]]
The ''Read GSSHA Solution'' dialog allows previously saved GSSHA solutions to be imported into a GSSHA project. The dialog contains the following information:
*''Simulation'' &ndash; The selected GSSHA project file name containing solution data.
*''Path'' &ndash; The file path to the selected GSSHA project file.
*'''Select Simulation...''' &ndash; Brings up an ''Open'' dialog, allowing browsing to and selection of the desired GSSHA project file.
*''Solution file''' &ndash; Indicates whether the selected GSSHA project file contains solution data.


{{GSSHAMain
At the bottom of the dialog are the following buttons:
*'''Help''' &ndash; Opens this article in a web browser.
*'''OK''' &ndash; Saves and changes, closes the ''Read GSSHA Solution'' dialog, and imports the solution data. The solution data will be within a [[File:Generic Folder Locked.svg|14px]] GSSHA solutions folder.
*'''Cancel''' &ndash; Discards and changes and closes the ''Read GSSHA Solution'' dialog.


|PLinks=
==References==
* [http://gsshawiki.com/index.php?title=Overview:Overview Overview]
{{reflist}}
|GUMLinks=
* [http://gsshawiki.com/index.php?title=Introduction:Introduction Introduction]


}}
 
{{GSSHA Wiki}}
{{WMSMain}}
 
[[Category:GSSHA|G]]
[[Category:GSSHA Dialogs|G]]
[[Category:External Links]]
[[Category:Link to Store]]

Latest revision as of 23:05, 13 May 2021


Gridded Surface Subsurface Hydrologic Analysis (GSSHA) is a two-dimensional finite difference rainfall/runoff model. A finite difference grid is used to establish the computational domain and parameters for surface runoff. The GSSHA model is fully coupled with hydraulic stream flow/routing models. Parameters for stream channels are defined using arcs and then mapped to the appropriate underlying grid cells.

Features of GSSHA include 1D stream flow and infiltration, 2D overland flow and groundwater, and full coupling between the groundwater, shallow soils, streams, and overland flow.[1] "Sediment and constituent fate and transport are simulated in the shallow soils, overland flow plane, and in streams and channels. GSSHA can be used as an episodic or continuous model where soil surface moisture, groundwater levels, stream interactions, and constituent fate are continuously simulated. The fully coupled groundwater to surface-water interaction allows GSSHA to model basins in both arid and humid environments."[1]

The GSSHA model can be added to a paid edition of WMS.[2]

GSSHA Menus

There are two GSSHA menus in WMS:

  • When in the Map Module Map Module Icon.svg, the GSSHA menu is available when a GSSHA coverage is selected. See here for more details.
  • When in the 2-D Grid Module 2D Grid Icon.svg, the main GSSHA menu is available. See here for more details.

Cell Properties

The 2D grid cell properties include an I,J location and a scalar or index map value. The scalar or index map value is associated with the currently selected dataset in the Project Explorer and can be edited in the Properties Window. The I,J location can be viewed but not edited in the Properties Window. The 2D grid contours are a way of visualizing the spatial variation of the scalar or index map values for the selected dataset.

GSSHA Model Check

GSSHA Model Check dialog

The GSSHA Model Check dialog lists potential problems with the GSSHA model. It is accessed by selecting GSSHA | Model Check... while in the 2-D Grid Module 2D Grid Icon.svg. The model check runs through the input data for a GSSHA simulation and looks for obvious inconsistencies and problems with the model. The model check will find logical problems, but will not identify values that are outside of plausible ranges.

An example of a problem that the model checker would not find is if a stream arc has a pit that pools water. Examples of potential problems that will be identified by the model check:

  • An index map has one or more cells whose ID is "0" (which is not allowed in GSSHA).
  • A specified process that has an ID with parameters whose values are "0.00" (which indicates an incomplete entry).

Clicking on a specific warning or error will open a dialog that will allow the potential problem to be fixed, if needed.

At the bottom of the dialog are three buttons:

  • Help – Opens this article in a web browser.
  • Done – Closes the GSSHA Model Check dialog.
  • Print – Opens a Choose name of output file dialog. Enter the desired File name and click Save to export the model check information to a text file.

GSSHA Run Options

GSSHA Run Options dialog

The GSSHA Run Options dialog lists options for running the GSSHA model. It is accessed by selecting GSSHA | Run GSSHA... while in the 2-D Grid Module 2D Grid Icon.svg.

The following sections and options are found in this dialog:

  • Location section – Lists the GSSHA project file that will be run. Click Open Macro.svg to open a Save GSSHA Project File dialog. Select the desired project, or enter a new File name and click Save to close the Save GSSHA Project File dialog.
  • Options section – The following options can be turned on or off:
    • Suppress screen printing – Suppresses the output of runtime data from GSSHA at each time step, significantly reducing the overall run time required for a GSSHA simulation. This option requires that the Save file before running be turned on.
    • Save file before running – Instructs GSSHA to save the project file prior to running GSSHA.
    • Pause GSSHA window after running

At the bottom of the dialog are the following buttons:

  • OK – Saves the changes and opens the Model Wrapper.
  • Cancel – Cancels the GSSHA model run and closes the GSSHA Run Options dialog.

Read GSSHA Solution

Read GSSHA Solution dialog

The Read GSSHA Solution dialog allows previously saved GSSHA solutions to be imported into a GSSHA project. The dialog contains the following information:

  • Simulation – The selected GSSHA project file name containing solution data.
  • Path – The file path to the selected GSSHA project file.
  • Select Simulation... – Brings up an Open dialog, allowing browsing to and selection of the desired GSSHA project file.
  • Solution file' – Indicates whether the selected GSSHA project file contains solution data.

At the bottom of the dialog are the following buttons:

  • Help – Opens this article in a web browser.
  • OK – Saves and changes, closes the Read GSSHA Solution dialog, and imports the solution data. The solution data will be within a Generic Folder Locked.svg GSSHA solutions folder.
  • Cancel – Discards and changes and closes the Read GSSHA Solution dialog.

References

  1. ^ a b "Overview:Overview". GSSHA Wiki. http://www.gsshawiki.com/Overview:Overview. Retrieved on April 26, 2019. 
  2. ^ "WMS Editions & Pricing". Aquaveo. http://www.aquaveo.com/software/wms-pricing. Retrieved on April 26, 2019.